0102030405
WENK Pneumatic 35A Series MAC Type High-Frequency Solenoid Valve
Product Detail
| Pressure Range | Vacunm~8 bar |
| Ambient Temperature | -18℃~50℃ |
| Operating Media | Compressed Air / Neutral Gas |
| Voltage Tolerance | -15%~+10% of rated voltage |
| Flow (CV Value) | 5.4W:Cv 0.15,1.8W:Cv0.08 (P=6 bar,△P=1 bar) |
| Lubrication Required | Lubrication-Free |
| Material | Aluminum Alloy |
35A Series MAC Type High-Frequency Solenoid Valve User Manual

Product Introduction
The 35A Series MAC Type High-Frequency Solenoid Valve from WENK Pneumatic represents a high-performance pneumatic control component featuring a balanced poppet design. This valve offers exceptional response speed, powerful shifting force, and extended service life, making it ideal for high-frequency, precision pneumatic control systems. It finds广泛 application in packaging machinery, marking equipment, automated production lines, and other industrial sectors.
Key Features:
- Balanced design, unaffected by inlet pressure variations
- Short-stroke construction for rapid response in milliseconds
- High-strength spring return ensures reliable reset under low pressure
- Modular design for easy installation and maintenance
- Multiple voltage options available to meet different application requirements

Installation Steps
-
Pre-installation Preparation
- Verify that the product model and specifications match system requirements
- Confirm that the power supply voltage matches the solenoid valve rating
- Ensure the medium is clean; a filter with 40μm or higher precision is recommended
- Remove impurities, oil contamination, and moisture from the pipeline
-
Installation Process
- Correctly connect the inlet port (P), working port (A/B), and exhaust port (R/S) according to the arrow indicator on the valve body
- Wrap PTFE tape in a clockwise direction, with wrapping length not exceeding 80% of the thread length
- Avoid excessive force during installation to prevent damage to the valve body and threads
- Ensure the coil is installed vertically upward; horizontal or inverted installation is not recommended
- Reserve sufficient maintenance space, with at least 100mm clearance above the coil
-
Electrical Connection
- Turn off the power supply before connecting wires according to the wiring diagram
- Ensure secure connections to prevent poor contact
- For explosion-proof models, comply with relevant explosion-proof standard requirements
- After wiring is complete, check insulation performance to ensure safety
Pre-installation Preparation
- Verify that the product model and specifications match system requirements
- Confirm that the power supply voltage matches the solenoid valve rating
- Ensure the medium is clean; a filter with 40μm or higher precision is recommended
- Remove impurities, oil contamination, and moisture from the pipeline
Installation Process
- Correctly connect the inlet port (P), working port (A/B), and exhaust port (R/S) according to the arrow indicator on the valve body
- Wrap PTFE tape in a clockwise direction, with wrapping length not exceeding 80% of the thread length
- Avoid excessive force during installation to prevent damage to the valve body and threads
- Ensure the coil is installed vertically upward; horizontal or inverted installation is not recommended
- Reserve sufficient maintenance space, with at least 100mm clearance above the coil
Electrical Connection
- Turn off the power supply before connecting wires according to the wiring diagram
- Ensure secure connections to prevent poor contact
- For explosion-proof models, comply with relevant explosion-proof standard requirements
- After wiring is complete, check insulation performance to ensure safety

Operation Guide
-
Initial Use
- Manually test valve core movement for flexibility before powering on
- Slowly open the air supply and check for leaks
- Gradually adjust the working pressure to the rated value
- Perform no-load testing to confirm normal solenoid valve operation
-
Normal Operation
- Ensure working pressure remains within the rated range
- Avoid frequent start-stop cycles to reduce unnecessary valve operations
- Regularly check operating status to ensure proper solenoid valve response
- Record operating parameters and establish maintenance records
-
Special Working Condition Handling
- Implement anti-freezing measures when used in low-temperature environments
- Enhance waterproof and moisture-proof measures in humid environments
- Take shock absorption measures in high-vibration applications
- Monitor coil temperature during high-frequency operations
Initial Use
- Manually test valve core movement for flexibility before powering on
- Slowly open the air supply and check for leaks
- Gradually adjust the working pressure to the rated value
- Perform no-load testing to confirm normal solenoid valve operation
Normal Operation
- Ensure working pressure remains within the rated range
- Avoid frequent start-stop cycles to reduce unnecessary valve operations
- Regularly check operating status to ensure proper solenoid valve response
- Record operating parameters and establish maintenance records
Special Working Condition Handling
- Implement anti-freezing measures when used in low-temperature environments
- Enhance waterproof and moisture-proof measures in humid environments
- Take shock absorption measures in high-vibration applications
- Monitor coil temperature during high-frequency operations

Maintenance
-
Daily Maintenance
- Regularly clean the exterior of the valve body to maintain a clean surface
- Check for loose connections and tighten as necessary
- Observe the exhaust port for any abnormal conditions
- Record operating time and number of cycles
-
Periodic Maintenance
- Inspect the filter every 3 months and clean or replace the filter element as needed
- Check the condition of seals every 6 months and replace if aging is detected
- Conduct a comprehensive inspection annually, including coil insulation performance testing
- Adjust maintenance intervals based on usage frequency and environmental conditions
-
Long-term Storage
- Thoroughly clean the interior of the valve body before storage
- Disconnect power and air supply, and drain internal media
- Seal the interfaces to prevent dust ingress
- Store in a dry, well-ventilated environment away from direct sunlight
Daily Maintenance
- Regularly clean the exterior of the valve body to maintain a clean surface
- Check for loose connections and tighten as necessary
- Observe the exhaust port for any abnormal conditions
- Record operating time and number of cycles
Periodic Maintenance
- Inspect the filter every 3 months and clean or replace the filter element as needed
- Check the condition of seals every 6 months and replace if aging is detected
- Conduct a comprehensive inspection annually, including coil insulation performance testing
- Adjust maintenance intervals based on usage frequency and environmental conditions
Long-term Storage
- Thoroughly clean the interior of the valve body before storage
- Disconnect power and air supply, and drain internal media
- Seal the interfaces to prevent dust ingress
- Store in a dry, well-ventilated environment away from direct sunlight

Troubleshooting
-
Solenoid Valve Fails to Operate
- Possible Causes
- Power supply not connected or insufficient voltage
- Burned or damaged coil
- Stuck valve core or foreign object blockage
- Abnormal control signal
- Solutions
- Check power connections and voltage
- Measure coil resistance to confirm normal operation
- Disassemble and clean the valve core to remove foreign objects
- Inspect control signal wiring
-
Solenoid Valve Leakage
- Possible Causes
- Worn or aging seals
- Loose connections
- Damaged valve body or core
- Pressure exceeding rated value
- Solutions
- Replace seals
- Tighten connection points
- Inspect valve body and core, replace if necessary
- Adjust working pressure to within rated range
-
Slow Response
- Possible Causes
- Insufficient air supply pressure
- Clogged filter
- Worn valve core
- Aging coil
- Solutions
- Check the air supply system to ensure normal pressure
- Clean or replace the filter
- Inspect valve core for wear, replace if necessary
- Test coil performance, replace if necessary
-
Abnormal Noise
- Possible Causes
- Unstable air supply pressure
- Loose valve body
- Worn valve core
- Improper installation
- Solutions
- Check the air supply system and install a pressure stabilizing device
- Tighten the valve body and connections
- Inspect valve core for wear, replace if necessary
- Reinstall to meet requirements
Solenoid Valve Fails to Operate
- Possible Causes
- Power supply not connected or insufficient voltage
- Burned or damaged coil
- Stuck valve core or foreign object blockage
- Abnormal control signal
- Solutions
- Check power connections and voltage
- Measure coil resistance to confirm normal operation
- Disassemble and clean the valve core to remove foreign objects
- Inspect control signal wiring
Solenoid Valve Leakage
- Possible Causes
- Worn or aging seals
- Loose connections
- Damaged valve body or core
- Pressure exceeding rated value
- Solutions
- Replace seals
- Tighten connection points
- Inspect valve body and core, replace if necessary
- Adjust working pressure to within rated range
Slow Response
- Possible Causes
- Insufficient air supply pressure
- Clogged filter
- Worn valve core
- Aging coil
- Solutions
- Check the air supply system to ensure normal pressure
- Clean or replace the filter
- Inspect valve core for wear, replace if necessary
- Test coil performance, replace if necessary
Abnormal Noise
- Possible Causes
- Unstable air supply pressure
- Loose valve body
- Worn valve core
- Improper installation
- Solutions
- Check the air supply system and install a pressure stabilizing device
- Tighten the valve body and connections
- Inspect valve core for wear, replace if necessary
- Reinstall to meet requirements

Our Commitments & Core Advantages
1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.