WENK Pneumatic CRB2 Series Vane-type Rotary Cylinder
Product Detail(Single Vane Specifications)
| Bore | Φ10mm | Φ15mm | Φ20mm | Φ30mm | Φ40mm | |
| Working Media | Cleaned Air | |||||
| Angular Stroke | 90° | 180° | 270° | |||||
| Working Temperature Range | 5℃~60℃ | |||||
| Maximum Pressure | 0.7Mpa | 1.0Mpa | ||||
| Minimum Pressure | 0.2Mpa | 0.15Mpa | ||||
| Rotation Time Adjustment Range | 0.03~0.3 | 0.04~0.3 | 0.07~0.5 | |||
| Permissible Kinetic Energy J |
Cushion with Seal Kit | 0.0015 | 0.001 | 0.003 | 0.02 | 0.04 |
| Cushion only | 0.00025 | 0.0004 | 0.015 | 0.03 | ||
| Shaft Load (N) | Permissible Radial Load | 15 | 15 | 25 | 30 | 60 |
| Permissible Axial Load | 10 | 10 | 20 | 25 | 40 | |
| Through Hole Location | Body Side or Axial Direction | |||||
| Port Size (Body Side, Axial Direction) | M3 x 0.5 | M5 x 0.8 | ||||
| Angular Adjustment Range | 0-230° | 0-240° | 0-230° | |||
Product Detail(Double Vane Specifications)
| Bore | Φ10mm | Φ15mm | Φ20mm | Φ30mm | Φ40mm | |
| Working Media | Cleaned Air | |||||
| Angular Stroke | 90° | 100° | |||||
| Working Temperature Range | 5℃~60℃ | |||||
| Maximum Pressure | 0.7Mpa | 1.0Mpa | ||||
| Minimum Pressure | 0.2Mpa | 0.15Mpa | ||||
| Rotation Time Adjustment Range | 0.03~0.3 | 0.04~0.3 | 0.07~0.5 | |||
| Permissible Kinetic Energy J | 0.0003 | 0.0012 | 0.0033 | 0.02 | 0.04 | |
| Shaft Load (N) | Permissible Radial Load | 15 | 15 | 25 | 30 | 60 |
| Permissible Axial Load | 10 | 10 | 20 | 25 | 40 | |
| Through Hole Location | Body Side or Axial Direction | |||||
| Port Size (Body Side, Axial Direction) | M3 x 0.5 | M5 x 0.8 | ||||
| Angular Adjustment Range | 0-90° | |||||
CRB2 Series Vane Type Rotary Cylinder User Guide

Product Overview
The CRB2 series vane type rotary cylinder represents WENK Pneumatic's compact pneumatic rotary actuator designed for precise angular motion control in automated systems. Featuring an innovative vane structure, these cylinders achieve rotational movement through compressed air drive, making them ideal for positioning, indexing, flipping, and sorting applications in automation scenarios.
The CRB2 series offers both single vane and double vane configurations. Single vane models provide 90°, 180°, or 270° rotation, while double vane models offer 90° or 100° rotation. Bore sizes range from 10mm to 40mm, catering to different torque and installation space requirements. The aluminum alloy body construction ensures strength while reducing weight, making it suitable for weight-sensitive applications.
Equipped with a built-in angle adjustment mechanism, these cylinders allow precise rotation angle adjustment. Multiple mounting options and port configurations provide flexible installation possibilities. Magnetic switches can be optionally integrated for precise rotational position detection and control.

Product Specifications
Basic Parameters
- Bore sizes: 10mm, 15mm, 20mm, 30mm, 40mm
- Configuration options:
- Single vane type: 90°, 180°, 270° rotation angles
- Double vane type: 90°, 100° rotation angles
- Action type: Double acting
- Operating pressure range:
- 10mm bore: 0.2~0.7MPa
- 15~40mm bore: 0.15~0.7MPa
- Maximum operating pressure: 1.05MPa
- Ambient and fluid temperature: -10~70°C
- Rotation time adjustment range (seconds/90°):
- 10mm bore: 0.03~0.3 seconds
- 15~20mm bore: 0.04~0.3 seconds
- 30~40mm bore: 0.07~0.5 seconds
- Allowable kinetic energy:
- 10mm bore: 0.0003J
- 15mm bore: 0.0012J
- 20mm bore: 0.0033J
- 30mm bore: 0.02J
- 40mm bore: 0.04J
- Allowable shaft load:
- Radial load: 15N (10~15mm), 25N (20mm), 30N (30mm), 60N (40mm)
- Thrust load: 10N (10~15mm), 20N (20mm), 25N (30mm), 40N (40mm)
- Port location: Side ported or axial ported (side ported only when switch and angle adjuster are installed)
- Port size: M3×0.5 (10mm), M5×0.8 (15~40mm)
- Angle adjustment range: 0~90° (for 100° models)
- Single vane type: 90°, 180°, 270° rotation angles
- Double vane type: 90°, 100° rotation angles
- 10mm bore: 0.2~0.7MPa
- 15~40mm bore: 0.15~0.7MPa
- 10mm bore: 0.03~0.3 seconds
- 15~20mm bore: 0.04~0.3 seconds
- 30~40mm bore: 0.07~0.5 seconds
- 10mm bore: 0.0003J
- 15mm bore: 0.0012J
- 20mm bore: 0.0033J
- 30mm bore: 0.02J
- 40mm bore: 0.04J
- Radial load: 15N (10~15mm), 25N (20mm), 30N (30mm), 60N (40mm)
- Thrust load: 10N (10~15mm), 20N (20mm), 25N (30mm), 40N (40mm)
Torque Output (N·m)
- 10mm bore:
- 0.5MPa: 0.025
- 0.7MPa: 0.035
- 15mm bore:
- 0.5MPa: 0.07
- 0.7MPa: 0.10
- 20mm bore:
- 0.5MPa: 0.16
- 0.7MPa: 0.22
- 30mm bore:
- 0.5MPa: 0.54
- 0.7MPa: 0.76
- 40mm bore:
- 0.5MPa: 1.15
- 0.7MPa: 1.60
- 0.5MPa: 0.025
- 0.7MPa: 0.035
- 0.5MPa: 0.07
- 0.7MPa: 0.10
- 0.5MPa: 0.16
- 0.7MPa: 0.22
- 0.5MPa: 0.54
- 0.7MPa: 0.76
- 0.5MPa: 1.15
- 0.7MPa: 1.60

Installation Steps
-
Pre-installation preparation
- Confirm that the cylinder model and specifications meet application requirements
- Inspect the cylinder for any external damage
- Clean the mounting surface to ensure no impurities or burrs
- Prepare necessary installation tools and accessories
-
Mounting method selection
- Direct mounting: Fix the cylinder body directly to the mounting surface
- Flange mounting: Use flange accessories for installation
- Trunnion mounting: Use trunnion accessories for installation
- Select the appropriate mounting method based on actual application scenarios
-
Angle adjustment
- Loosen the angle adjustment bolts
- Rotate the cylinder to the desired angle
- Tighten the angle adjustment bolts
- Ensure angle adjustment is within the specified range
-
Piping connection
- Confirm port location (side or axial)
- Connect to M3 or M5 ports using appropriate air tubes and fittings
- Ensure proper piping seal to prevent leaks
- Install speed controllers if necessary
-
Magnetic switch installation (optional)
- Select the appropriate magnetic switch model
- Install the magnetic switch in the switch groove of the cylinder body
- Adjust the switch position to ensure triggering at the desired position
- Connect switch signal wires to the control system
Pre-installation preparation
- Confirm that the cylinder model and specifications meet application requirements
- Inspect the cylinder for any external damage
- Clean the mounting surface to ensure no impurities or burrs
- Prepare necessary installation tools and accessories
Mounting method selection
- Direct mounting: Fix the cylinder body directly to the mounting surface
- Flange mounting: Use flange accessories for installation
- Trunnion mounting: Use trunnion accessories for installation
- Select the appropriate mounting method based on actual application scenarios
Angle adjustment
- Loosen the angle adjustment bolts
- Rotate the cylinder to the desired angle
- Tighten the angle adjustment bolts
- Ensure angle adjustment is within the specified range
Piping connection
- Confirm port location (side or axial)
- Connect to M3 or M5 ports using appropriate air tubes and fittings
- Ensure proper piping seal to prevent leaks
- Install speed controllers if necessary
Magnetic switch installation (optional)
- Select the appropriate magnetic switch model
- Install the magnetic switch in the switch groove of the cylinder body
- Adjust the switch position to ensure triggering at the desired position
- Connect switch signal wires to the control system

Operation Guide
-
Pre-start checks
- Confirm air supply pressure is within the specified range
- Check for correct piping connections
- Ensure operating temperature is within the allowable range
- Verify secure installation of the cylinder
- Confirm angle adjustment is correct
-
Basic operation
- Forward rotation: Compressed air enters from one port, driving the vane to rotate
- Reverse rotation: Compressed air enters from the other port, driving the vane to rotate in the opposite direction
- Double acting cylinders provide power in both directions for bidirectional rotation
-
Pressure adjustment
- Adjust operating air pressure according to application requirements
- Higher air pressure results in greater cylinder output torque
- Ensure air pressure does not exceed the maximum operating pressure of 0.7MPa
- Select the appropriate minimum operating pressure based on bore size
-
Speed adjustment
- Adjust rotation speed using speed controllers
- Turn the speed controller knob clockwise to decrease speed
- Turn the speed controller knob counterclockwise to increase speed
- Ensure speed is within the specified range
-
Load considerations
- Ensure the load does not exceed the cylinder's maximum allowable load
- Avoid radial and thrust loads exceeding specified values
- Consider the effect of inertial forces on the cylinder
- Avoid sudden loading or unloading during rotation
Pre-start checks
- Confirm air supply pressure is within the specified range
- Check for correct piping connections
- Ensure operating temperature is within the allowable range
- Verify secure installation of the cylinder
- Confirm angle adjustment is correct
Basic operation
- Forward rotation: Compressed air enters from one port, driving the vane to rotate
- Reverse rotation: Compressed air enters from the other port, driving the vane to rotate in the opposite direction
- Double acting cylinders provide power in both directions for bidirectional rotation
Pressure adjustment
- Adjust operating air pressure according to application requirements
- Higher air pressure results in greater cylinder output torque
- Ensure air pressure does not exceed the maximum operating pressure of 0.7MPa
- Select the appropriate minimum operating pressure based on bore size
Speed adjustment
- Adjust rotation speed using speed controllers
- Turn the speed controller knob clockwise to decrease speed
- Turn the speed controller knob counterclockwise to increase speed
- Ensure speed is within the specified range
Load considerations
- Ensure the load does not exceed the cylinder's maximum allowable load
- Avoid radial and thrust loads exceeding specified values
- Consider the effect of inertial forces on the cylinder
- Avoid sudden loading or unloading during rotation

Maintenance
-
Daily inspection
- Check for piping leaks
- Verify smooth operation of the cylinder
- Check for loose mounting bolts
- Confirm if the cylinder has abnormal noise or vibration
-
Regular maintenance
- Every 3 months:
- Clean the exterior of the cylinder
- Check installation status
- Verify operational performance
- Every 6 months:
- Check the condition of seals
- Perform functional testing
- Annually:
- Check vane and shaft wear
- Inspect internal spring performance
-
Lubrication
- The CRB2 series is designed for maintenance-free operation and typically does not require additional lubrication
- For long-term use or in harsh environments, add an appropriate amount of lubricating oil as needed
- Use the recommended lubricant type and avoid incompatible lubricants
-
Storage and handling
- Store in a dry, clean environment away from direct sunlight
- Avoid storage temperatures below -10°C or above 70°C
- Avoid severe impact and vibration during handling
- Inspect the cylinder for damage before installation
Daily inspection
- Check for piping leaks
- Verify smooth operation of the cylinder
- Check for loose mounting bolts
- Confirm if the cylinder has abnormal noise or vibration
Regular maintenance
- Every 3 months:
- Clean the exterior of the cylinder
- Check installation status
- Verify operational performance
- Every 6 months:
- Check the condition of seals
- Perform functional testing
- Annually:
- Check vane and shaft wear
- Inspect internal spring performance
Lubrication
- The CRB2 series is designed for maintenance-free operation and typically does not require additional lubrication
- For long-term use or in harsh environments, add an appropriate amount of lubricating oil as needed
- Use the recommended lubricant type and avoid incompatible lubricants
Storage and handling
- Store in a dry, clean environment away from direct sunlight
- Avoid storage temperatures below -10°C or above 70°C
- Avoid severe impact and vibration during handling
- Inspect the cylinder for damage before installation

Safety Precautions
- Carefully read this user guide before operation
- Ensure air supply pressure is within the specified range to avoid equipment damage or safety accidents due to excessive pressure
- Cut off the air supply before installation and maintenance
- Avoid use in environments with corrosive gases, dust, or high temperatures unless the equipment is specially treated
- Do not exceed the rated load and operating frequency of the equipment
- Regularly inspect equipment status to detect and address potential issues promptly
- Immediately stop use and perform inspections if abnormal conditions are detected
- Avoid placing fingers or other body parts within the cylinder's movement range
- Use appropriate safety protection devices, such as protective covers or safety light curtains
- Release internal pressure before disassembling the cylinder
- Do not disassemble or modify the cylinder to avoid affecting safety performance
- Use original accessories when replacing parts