The CU series multi-position mounting cylinder is a versatile pneumatic actuator designed for space-constrained automated applications requiring flexible installation options. Featuring a compact rectangular design with multiple mounting surfaces, this cylinder allows direct installation on any side, eliminating the need for additional brackets and saving valuable space.

Available in bore sizes from 6mm to 32mm with strokes ranging from 5mm to 50mm, the CU cylinder offers versatile solutions for various industrial needs. It is available in double-acting, single-acting spring return, and single-acting spring extend configurations, with optional non-rotating piston rods for precise linear motion.

Engineered for efficiency, this cylinder operates at pressures between 0.15MPa and 0.7MPa, with a temperature range of -10°C to 60°C. Optional features include magnetic switches for position detection and air cushions for smooth end-of-stroke damping. Suitable for material handling, assembly, and automated testing, the CU multi-position mounting cylinder delivers reliable performance in a compact package.

    Product Detail

    Acting Mode

    Double Acting | Single-Acting

    Working Media

    Cleaned Air

    Working Pressure

    0.1-0.9Mpa(1-9kgf/cm²)

    Working Temperature Range

    -10℃~60℃

    Buffering Model

    Fixed buffer

    Body Material

    Aluminum Alloy

    CU Multi-Position Mounting Cylinder User Manual

    CU(1)

    1. Product Introduction

    The CU series multi-position mounting cylinder is a versatile pneumatic actuator designed specifically for space-constrained automated applications requiring flexible installation options. Featuring a compact rectangular design with multiple mounting surfaces, this cylinder allows direct installation on any side without additional brackets, saving valuable space.

    Product Features

    • Multi-position mounting design allows direct installation from multiple directions, saving space
    • Compact rectangular structure with high rigidity and torsional resistance
    • Multiple action types available: double-acting, single-acting spring return, single-acting spring extend
    • Optional non-rotating piston rod for precise linear motion
    • Rubber buffers on both ends for smooth operation and low noise
    • Magnetic switch mountable for precise position detection
    • Optional air cushion for smoother end-of-stroke damping
    • Multiple bore sizes and strokes available to meet different application requirements
    • Oil-free lubrication design for simple maintenance
    • Wide temperature range for strong environmental adaptability
    CU(2)

    2. Technical Parameters

    Basic Parameters

    • Action type: Double-acting, single-acting spring return, single-acting spring extend
    • Operating medium: Compressed air (filtered to 40μm or finer)
    • Operating pressure range: 0.15-0.7MPa
    • Pressure resistance: 1.0MPa
    • Ambient and fluid temperature: -10~60°C (with magnetic switch); -10~70°C (without magnetic switch)
    • Piston speed: 50~500mm/s
    • Lubrication method: Non-lube

    Specifications

    • Bore size: 6, 10, 16, 20, 25, 32mm
    • Stroke: 5, 10, 15, 20, 25, 30, 40, 50mm
    • Connection size: M5×0.8 (6, 10mm bore); G1/8 (16, 20, 25, 32mm bore)
    • Piston rod non-rotating accuracy: ±0.8° (6, 10mm bore); ±0.5° (16mm and above bore)
    • Stroke tolerance: +1.0/0mm
    • Theoretical thrust at 0.7MPa:
      • 6mm bore: 20N
      • 10mm bore: 53N
      • 16mm bore: 135N
      • 20mm bore: 212N
      • 25mm bore: 331N
      • 32mm bore: 543N
    CU(3)

    3. Installation Steps

    Pre-installation Preparation

    1. Confirm that the cylinder model matches the installation environment
    2. Check if the cylinder appearance is intact and undamaged
    3. Prepare necessary installation tools and accessories
    4. Ensure the installation surface is flat and clean

    Installation Process

    1. Select the appropriate mounting surface based on installation space and orientation requirements
    2. Secure the cylinder in the installation position using suitable bolts:
      • 6mm bore: M4 bolts
      • 10mm bore: M5 bolts
      • 16mm bore: M6 bolts
      • 20mm bore: M6 bolts
      • 25mm bore: M8 bolts
      • 32mm bore: M8 bolts
    3. Connect the air supply pipeline, ensuring secure connections
    4. Install the magnetic switch (if any) and adjust to the appropriate position
    5. Check that all connections are secure and without looseness

    Installation Precautions

    • Apply thread locker to mounting bolts to prevent loosening
    • Torque bolts according to specifications, avoiding over-tightening or under-tightening
    • Ensure coaxiality between the cylinder and load
    • Reserve sufficient buffer space to avoid collision
    • Ensure correct pipeline connection without leakage
    • Maintain appropriate spacing when installing multiple cylinders side by side
    • Avoid subjecting the cylinder to excessive radial load and moment during installation
    CU(4)

    4. Operation Guide

    Pre-operation Check

    1. Confirm that the air supply pressure is within the specified range
    2. Check that all connections are secure
    3. Ensure the working environment is clean with no impurities entering the cylinder
    4. If using a magnetic switch, confirm its proper operation

    Operation Procedure

    1. Slowly open the air supply valve to make the cylinder move slowly
    2. Observe if the cylinder operates smoothly without abnormal noise
    3. Test the working status of the magnetic switch (if any)
    4. Adjust the working pressure and flow as needed

    Operation Precautions

    • Avoid using beyond the rated pressure
    • Avoid long-term high-speed operation of the cylinder without lubrication
    • Do not strike the cylinder body and piston rod
    • Regularly check the cylinder operation status and stop for inspection if abnormalities are found
    • Avoid adjusting or disassembling components while the cylinder is in operation
    • Take care to protect the piston rod surface from scratches or contamination
    • Avoid subjecting the cylinder to excessive lateral loads
    CU(5)

    5. Maintenance

    Daily Maintenance

    1. Keep the cylinder exterior clean
    2. Check if the air supply pressure is stable
    3. Check for leaks at connection points
    4. Listen to the operating sound to determine if it is normal

    Regular Maintenance

    1. Weekly inspection:

      • Cylinder operation status
      • Fastening condition of connection parts
      • Magnetic switch working status
    2. Monthly inspection:

      • Piston rod surface condition
      • Buffering effect
      • Seal condition
    3. Quarterly inspection:

      • Internal condition of the cylinder
      • Replace worn seals
      • Comprehensive cylinder cleaning

    Maintenance Precautions

    • Use recommended lubricants
    • Avoid using corrosive cleaning agents
    • Ensure the air supply is turned off during maintenance
    • Pay attention to model matching when replacing seals
    • Use a clean soft cloth when cleaning the piston rod to avoid scratching the surface
    • Regularly check the reliability of magnetic switches
    CU多位置安装气缸CU_1CU_2

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset