Leave Your Message
WENK Pneumatic GF Series Air Filter
Products
Products Categories
Featured Products

WENK Pneumatic GF Series Air Filter

The WENK G-Series GF Air Filter is a premium Airtac-type pneumatic component designed for efficient compressed air purification. This compact unit effectively removes contaminants, moisture, and solid particles from compressed air systems.

Featuring a unique diversion structure that creates gas rotation, the GF filter enhances liquid separation and particle filtration. With standard 40μm filtration (optional 5μm precision), it reliably removes solid particles while maintaining low pressure loss and high water separation efficiency.

Constructed with high-quality aluminum alloy bodies and transparent PC bowls, the GF filter offers excellent durability and visibility for monitoring filter condition and water level. Various drainage options (manual, differential pressure, automatic) provide operational flexibility.

Ideal for industrial automation, CNC machines, and pneumatic control systems, the WENK G-Series GF Air Filter ensures clean air supply, protecting downstream equipment and extending service life.

    Product Detail

    Pressure Regulation Range

    Differential Pressure Drain:0.15~0.9Mpa
    Auto Drain:0.15~0.9Mpa

    Working Media

    Air

    Proof Pressure

    1.5Mpa

    Working Temperature Range

    -20℃~70℃

    Filtration Rating

    40μm

    Body Material

    Aluminum Alloy

    G-Series GF Air Filter User Manual

    GF(1)

    Product Overview

    The WENK G-Series GF Air Filter is a premium Airtac-type pneumatic component designed for compressed air purification. Featuring efficient filtration (standard 40μm, optional 5μm) and a unique diversion structure, it effectively removes moisture, oil mist, and solid particles from compressed air, providing clean air supply for pneumatic systems.

    Technical Specifications:

    • Working Medium: Compressed air
    • Operating Pressure: 0.1-1.0MPa
    • Proof Pressure: 1.5MPa
    • Operating Temperature: -20-70°C
    • Water Cup Capacity: 10-230cc (depending on model)
    • Filtration Precision: Standard 40μm, optional 5μm (customized)
    • Features: Unique diversion structure, multiple drainage options, transparent bowls for visibility, low pressure loss with high filtration efficiency
    GF(2)

    Installation Steps

    1. Pre-installation Preparation

    • Ensure the compressed air system is shut off and depressurized
    • Clean connecting pipes to remove foreign matter and impurities
    • Prepare necessary tools: wrench, thread seal tape, etc.
    • Check the air filter for any damage or defects

    2. Installation Direction

    • Strictly follow the air flow direction: Inlet → Filter → Outlet
    • Connect pipes according to the arrow indicators on the unit
    • Connect the inlet port to the upstream air source and the outlet port to downstream equipment

    3. Pipe Connection

    • Use thread seal tape on threaded connections to ensure proper sealing
    • Tighten connections evenly with a wrench, avoiding excessive force that may damage threads
    • Ensure all connections are secure and tight

    4. Mounting and Fixing

    • Use the dedicated mounting bracket, matching the convex groove with the body's concave groove
    • Secure with fixing plates and screws
    • Ensure vertical installation with drain valves facing downward

    5. Post-installation Check

    • Ensure all connections are secure and free from looseness
    • Verify that the filter is installed vertically
    • Confirm that the air flow direction matches the arrow indicators
    GF(3)

    Operation Guide

    1. Startup Procedure

    • Slowly open the upstream air source valve to gradually increase pressure
    • Check for any leakage in all components
    • Inspect transparent bowls for cracks or damage

    2. Drainage Operation

    • Automatic Drain: Drains automatically when water level reaches set value
    • Differential Pressure Drain: Drains automatically when pressure difference reaches set value
    • Manual Drain: Rotate the drain knob at the bottom of the bowl clockwise to open the drain valve
    • After draining, rotate the knob counterclockwise to close the valve
    • Daily inspection of drainage is recommended, with increased frequency in high-humidity environments

    3. Filter Element Condition Check

    • Observe the filter element condition through the transparent bowl
    • Replace the element when it appears visibly dirty or when outlet air volume decreases significantly
    GF(4)

    Maintenance

    1. Daily Inspection

    • Regularly check transparent bowls to observe condensed water level and filter element condition
    • Inspect all components for leakage
    • Check connecting pipes for damage

    2. Filter Maintenance

    • Filter Element Replacement:
      • Replace when the element appears visibly dirty or when outlet air volume decreases significantly
      • Replacement steps:
        1. Shut off air supply and relieve pressure
        2. Unscrew the filter bowl and remove the old element
        3. Clean the inner wall of the bowl
        4. Install the new element, ensuring proper sealing
        5. Reinstall the bowl securely

    3. Maintenance Schedule

    • Filter element replacement: Generally every 3-6 months, depending on usage environment
    • Drainage operation: At least once daily (except for automatic drain models)
    GF(5)

    Precautions

    1. Safety Precautions

    • Always shut off air supply and relieve pressure before installation and maintenance
    • Do not exceed the maximum operating pressure of 1.0MPa
    • Avoid use in high-temperature environments (temperature not exceeding 70°C)
    • Do not strike transparent bowls with sharp objects

    2. Usage Limitations

    • For compressed air systems only
    • Not suitable for corrosive gas environments
    • Avoid direct sunlight and strong vibrations
    • Some parts are made of PC material; keep away from organic solvents

    3. Troubleshooting

    • Filter clogging: Replace the filter element
    • Poor drainage: Check if the drain valve is clogged, clean or replace if necessary
    • Leakage: Check connections for tightness, replace seals if necessary
    GF(1)

    Frequently Asked Questions

    Q1: What is the correct installation direction for the air filter? 
    A1: Must be installed in the order of Inlet → Filter → Outlet, strictly following the air flow direction.

    Q2: How to determine if the filter element needs replacement? 
    A2: Replace when the element appears visibly dirty, when outlet air volume decreases significantly, or when pressure drop increases.

    Q3: What drainage options are available? 
    A3: Three drainage options are available: manual drain, differential pressure drain, and automatic drain, which can be selected according to the usage environment.

    Q4: How to handle leakage in the air filter? 
    A4: Check all connections for looseness and inspect seals for damage. Retighten or replace seals as necessary.

    Q5: What is the operating pressure range of the filter? 
    A5: The operating pressure range is 0.1-1.0MPa; do not exceed the maximum operating pressure.

    GF空气过滤器(亚德客型G系列)

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.

    Make an free consultant