WENK Pneumatic GR Series Regulator
Product Detail
Pressure Regulation Range |
Differential Pressure Drain:0.15~0.9Mpa |
Working Media |
Air |
Proof Pressure |
1.5Mpa |
Working Temperature Range |
-20℃~70℃ |
Filtration Rating |
40μm |
Body Material |
Aluminum Alloy |
G-Series GR Pressure Regulator User Manual

Product Overview
The WENK G-Series GR Pressure Regulator is a premium Airtac-type pneumatic component designed for precise pressure control in compressed air systems. Featuring a balanced pressure adjustment mechanism and press-in self-locking structure, it provides stable and reliable pressure regulation, ensuring consistent operating pressure for downstream pneumatic components.
Technical Specifications:
- Working Medium: Compressed air
- Operating Pressure: 0.1-1.0MPa
- Pressure Regulation Range: Standard type 0.05-0.9MPa; Low-pressure type max 0.4MPa
- Proof Pressure: 1.5MPa
- Operating Temperature: -20-70°C
- Features: Embedded pressure gauge, press-in self-locking mechanism, balanced pressure regulation, multiple mounting options

Installation Steps
1. Pre-installation Preparation
- Ensure the compressed air system is shut off and depressurized
- Clean connecting pipes to remove foreign matter and impurities
- Prepare necessary tools: wrench, thread seal tape, etc.
- Check the pressure regulator for any damage or defects
2. Installation Position and Direction
- Installation Position: Should be installed after the filter, near the pneumatic components requiring stable pressure
- Installation Sequence: Filter → Regulator → Pneumatic components
- Installation Direction: Connect pipes according to the arrow indicators on the unit, ensuring correct air flow direction
3. Pipe Connection
- Use thread seal tape on threaded connections to ensure proper sealing
- Tighten connections evenly with a wrench, avoiding excessive force that may damage threads
- Ensure all connections are secure and tight
4. Mounting and Fixing
- Panel Mounting: Directly install on the control panel
- Bracket Mounting: Use the dedicated mounting bracket, matching the convex groove with the body's concave groove
- Secure with fixing plates and screws
5. Post-installation Check
- Ensure all connections are secure and free from looseness
- Confirm that the air flow direction matches the arrow indicators
- Check if the pressure gauge is intact

Operation Guide
1. Pressure Adjustment Operation
-
Pressure Adjustment:
- Pull up the pressure adjustment knob, turn clockwise to increase pressure, counterclockwise to decrease
- After adjusting to the desired pressure, push down the knob to lock in position
- Adjust pressure gradually and evenly to the required value, avoiding one-step adjustment
- Monitor output pressure through the pressure gauge
-
Pressure Calibration:
- Use the movable pointer to mark the working pressure range
- Move the pointer to the desired pressure position for easy identification of working pressure
2. Startup Procedure
- Slowly open the upstream air source valve to gradually increase pressure
- Check for any leakage in all components
- Observe if the pressure gauge reading is stable
- Confirm that the pressure regulator is working normally
3. Daily Monitoring
- Regularly check the pressure gauge reading to ensure stable pressure
- Check all connection points for leakage
- Confirm that the pressure regulator is working normally without abnormal noise

Maintenance
1. Daily Inspection
- Regularly check the pressure gauge reading to ensure stable pressure
- Inspect all components for leakage
- Check connecting pipes for damage
- Verify that the pressure regulator is working normally
2. Regulator Maintenance
-
Cleaning:
- Regularly clean the exterior of the pressure regulator to remove dust and dirt
- Cleaning steps:
- Shut off air supply and relieve pressure
- Wipe the valve body and pressure gauge with a clean cloth
- Check if the pressure gauge glass is intact
-
Pressure Gauge Maintenance:
- Regularly check the accuracy of pressure gauge readings
- If inaccurate readings are found, calibrate or replace the gauge promptly
3. Maintenance Schedule
- Pressure check: Daily
- External cleaning: Weekly
- Pressure gauge calibration: Every 6 months
- Comprehensive inspection: Every 12 months

Precautions
1. Safety Precautions
- Always shut off air supply and relieve pressure before installation and maintenance
- Do not exceed the maximum operating pressure of 1.0MPa
- Avoid use in high-temperature environments (temperature not exceeding 70°C)
- Do not strike the pressure gauge with sharp objects
2. Usage Limitations
- For compressed air systems only
- Not suitable for corrosive gas environments
- Avoid direct sunlight and strong vibrations
- Some parts are made of aluminum alloy; avoid severe impact
3. Troubleshooting
-
Unable to adjust pressure:
- Check if the adjustment knob is locked
- Check if the pressure spring is damaged
- Check if the valve core is clogged
-
Unstable pressure:
- Check if the air source pressure is stable
- Check if there are impurities inside the pressure regulator
- Check if the pressure gauge is damaged
-
Leakage:
- Check if connection points are loose
- Check if seals are damaged
- Replace seals if necessary

Frequently Asked Questions
Q1: What is the correct installation position and sequence for the regulator?
A1: Should be installed after the filter, near the pneumatic components requiring stable pressure. Installation sequence: Filter → Regulator → Pneumatic components.
Q2: How to adjust the pressure?
A2: Pull up the pressure adjustment knob, turn clockwise to increase pressure, counterclockwise to decrease. After adjusting to the desired pressure, push down the knob to lock in position.
Q3: How to determine if the pressure regulator is working properly?
A3: Observe if the pressure gauge reading is stable, if there is any leakage at connection points, and if the regulator operates without abnormal noise.
Q4: How to handle unstable pressure in the regulator?
A4: Check if the air source pressure is stable, if there are impurities inside the regulator, and if the pressure gauge is damaged. Clean the interior of the regulator or replace the pressure gauge if necessary.
Q5: What is the maintenance cycle for the regulator?
A5: Pressure check daily, external cleaning weekly, pressure gauge calibration every 6 months, and comprehensive inspection every 12 months.