| Model | HSV-06 | HSV-08 | HSV-10 | HSV-15 | |
| Working Media | Clean air | ||||
| Max.Working Pressure | 0.8Mpa | ||||
| Proof Pressure | 1.0MPa | ||||
| Working Temperature Range | 0℃~70℃ | ||||
| Port Size | PT1/8 | PT1/4 | PT3/8 | PT1/2 | |
| Lubrication | No Need | ||||
| Material | Body | Aluminum Alloy | |||
| Seal | NBR | ||||
HSV Series Hand Slide Valve User Guide

Product Overview
The HSV Series Hand Slide Valve is a high-quality manual control component designed by WENK Pneumatic. Operated by sliding the valve body, it controls pneumatic circuits with compact structure and reliable performance, suitable for various industrial automation applications.

Technical Specifications
-
Model Specifications
- HSV-06: G1/8" Port
- HSV-08: G1/4" Port
- HSV-10: G3/8" Port
- HSV-15: G1/2" Port
Working Medium: Clean compressed air filtered with 40μm filter
Working Pressure Range: 0-0.8MPa
Ambient Temperature: 0~70℃
Body Material: Aluminum Alloy
Seal Material: NBR (Nitrile Butadiene Rubber)
Operation Method: Manual Sliding
Model Specifications
- HSV-06: G1/8" Port
- HSV-08: G1/4" Port
- HSV-10: G3/8" Port
- HSV-15: G1/2" Port
Working Medium: Clean compressed air filtered with 40μm filter
Working Pressure Range: 0-0.8MPa
Ambient Temperature: 0~70℃
Body Material: Aluminum Alloy
Seal Material: NBR (Nitrile Butadiene Rubber)
Operation Method: Manual Sliding

Installation Steps
-
Confirm Installation Location
- Select a location convenient for operation
- Ensure sufficient operating space around the valve
- Avoid installation in high temperature, humid, or corrosive environments
-
Connect Air Supply
- Confirm air supply pressure is within 0-1.0MPa range
- Connect air inlet (P), outlet (A), and exhaust (R) according to valve markings
- Use appropriate sealing materials to ensure tight connections
-
Secure the Valve Body
- Use brackets or install directly on the pipeline as needed
- Ensure the valve body does not move or vibrate during operation
Confirm Installation Location
- Select a location convenient for operation
- Ensure sufficient operating space around the valve
- Avoid installation in high temperature, humid, or corrosive environments
Connect Air Supply
- Confirm air supply pressure is within 0-1.0MPa range
- Connect air inlet (P), outlet (A), and exhaust (R) according to valve markings
- Use appropriate sealing materials to ensure tight connections
Secure the Valve Body
- Use brackets or install directly on the pipeline as needed
- Ensure the valve body does not move or vibrate during operation

Operation Guide
-
Basic Operation
- Slide to "ON" position: Valve opens, air supply connected, compressed air flows from P port to A port
- Slide to "OFF" position: Valve closes, air supply disconnected, while A port connects to R port to exhaust residual air downstream
-
Operation Precautions
- Slide operation should be performed smoothly, avoiding excessive force
- Regularly check if the sliding mechanism operates smoothly
- Avoid use in vibrating environments to prevent accidental valve position change
Basic Operation
- Slide to "ON" position: Valve opens, air supply connected, compressed air flows from P port to A port
- Slide to "OFF" position: Valve closes, air supply disconnected, while A port connects to R port to exhaust residual air downstream
Operation Precautions
- Slide operation should be performed smoothly, avoiding excessive force
- Regularly check if the sliding mechanism operates smoothly
- Avoid use in vibrating environments to prevent accidental valve position change

Maintenance
-
Daily Inspection
- Check for air leakage at all connection points
- Ensure smooth sliding operation without sticking
- Clean dust and debris from the valve body surface
-
Regular Maintenance
- Every 3 months: Inspect and clean the air inlet filter
- Every 6 months: Check the condition of seals and replace if necessary
- Annually: Perform comprehensive performance testing
-
Lubrication
- No additional lubrication required
- If increased operating resistance is noticed, add a small amount of pneumatic-specific lubricating oil to sliding parts
Daily Inspection
- Check for air leakage at all connection points
- Ensure smooth sliding operation without sticking
- Clean dust and debris from the valve body surface
Regular Maintenance
- Every 3 months: Inspect and clean the air inlet filter
- Every 6 months: Check the condition of seals and replace if necessary
- Annually: Perform comprehensive performance testing
Lubrication
- No additional lubrication required
- If increased operating resistance is noticed, add a small amount of pneumatic-specific lubricating oil to sliding parts

Safety Precautions
- Ensure air supply is cut off before installation and maintenance
- Do not exceed the rated pressure
- Avoid use in environments with explosive gases
- Regularly inspect valve condition and stop use immediately if abnormalities are found
- Non-professionals should not disassemble internal valve structures

Our Commitments & Core Advantages
1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.