WENK Pneumatic IR Series Precision Pressure Reducing Valve
Product Detail
| Model | IR1000-01 | IR1010-01 | IR1020-01 | IR2000-02 | IR2010-02 | IR2020-02 | IR3000-03 | IR3010-03 | IR3020-03 |
| Working Media | Clean air | ||||||||
| Min.Working Pressure | 0.05MPa | ||||||||
| Pressure Range | 0.005~0.2MPa | 0.01~0.4MPa | 0.01~0.8MPa | 0.005~0.2MPa | 0.01~0.4MPa | 0.01~0.8MPa | 0.005~0.2MPa | 0.01~0.4MPa | 0.01~0.8MPa |
| Max.Working Pressure | 1.0MPa | ||||||||
| Pressure Gauge | Y40-01 | ||||||||
| Measurement Range | 0.25Mpa | 0.5Mpa | 1Mpa | 0.25Mpa | 0.5Mpa | 1Mpa | 0.25Mpa | 0.5Mpa | 1Mpa |
| Sensitivity | Within 0.2% of full scale | ||||||||
| Repeatability | Within ± 0.5% of full scale | ||||||||
| Air Consumption | Max. 3.5L/min is under pressure 1.0MPa | Max. 3.1L/min is under pressure 1.0MPa | Drain Port:Max. 9.5L/min is under pressure 1.0MPa | ||||||
| Ambient Temperature | -5℃~60℃(Not Frozen) | ||||||||
| Body Material | Aluminum Alloy | ||||||||
IR Precision Regulator User Manual

Technical Specifications
- Model: IR Series (IR1000, IR2000, IR3000)
- Pressure Regulation Range:
- IR1000/2000 Series: 0.005-0.2MPa, 0.01-0.4MPa, 0.01-0.8MPa
- IR3000 Series: 0.01-0.2MPa, 0.01-0.4MPa, 0.01-0.8MPa
- Maximum Supply Pressure: 1.0MPa
- Sensitivity: 0.2% (full span)
- Repeatability: ±0.5% (full span)
- Operating Temperature Range: -5°C to 60°C
- Port Size:
- IR1000 Series: 1/8"
- IR2000 Series: 1/4"
- IR3000 Series: 1/4", 3/8", 1/2"
- Materials:
- Body: Aluminum alloy
- Seals: Nitrile rubber or fluororubber
- Adjusting Knob: Engineering plastic

Installation Steps
-
Pre-installation Preparation:
- Verify that the regulator model and specifications meet system requirements
- Inspect the regulator for any damage or defects
- Prepare necessary installation tools and sealing materials
-
Installation Location:
- Install after the air filter and before the lubricator
- Ensure good ventilation and easy access for operation and maintenance
- Leave sufficient space for pressure adjustment and pressure gauge observation
-
Installation Direction:
- Install according to the arrow indicator on the valve body to ensure correct air flow direction
- Vertical installation with the adjusting knob facing upward is recommended for easy operation
-
Piping Connection:
- Use appropriate sealing material (such as PTFE tape) on threads
- Ensure secure connections without leakage
- Install pressure gauges to monitor inlet and outlet pressure

Operation Guide
-
Pressure Adjustment:
- Press the adjusting knob to unlock
- Clockwise rotation: Increase outlet pressure
- Counterclockwise rotation: Decrease outlet pressure
- After adjusting to the desired pressure, press the knob again to lock
-
Pressure Monitoring:
- Monitor the outlet pressure through the installed pressure gauge
- Regularly check pressure stability to ensure it remains within the set range
-
Start-up and Shutdown:
- Slowly open the upstream valve to avoid pressure shock
- When shutting down, first close the upstream valve, then release system pressure

Maintenance
-
Regular Inspection:
- Weekly check for leaks
- Monthly check for pressure setting drift
- Quarterly check overall performance
-
Cleaning and Maintenance:
- Regularly clean the exterior of the valve body to remove dust and impurities
- If performance degradation is noticed, disassemble and clean internal components
- Use neutral cleaning agents; avoid corrosive solvents
-
Component Replacement:
- Promptly replace aging or damaged seals
- Annual replacement of wearing parts is recommended to ensure optimal performance

Precautions
-
Safety Warnings:
- Always shut off the air supply before installation and maintenance
- Do not exceed the maximum inlet pressure
- Avoid use in environments with corrosive gases
-
Usage Limitations:
- For compressed air only; not suitable for other gases
- Do not use outside the specified temperature range
- Inlet air must be filtered to 5μm and oil-free
-
Troubleshooting:
- If outlet pressure is unstable, check if the air supply pressure is stable
- If leakage occurs, check connections for tightness and inspect seals for damage
- If pressure cannot be adjusted, check if internal components are blocked or damaged

Frequently Asked Questions
Q: What should I do if the regulator cannot reach the set pressure? A: Check if the inlet pressure is sufficient, ensuring it is at least 0.05MPa above the required outlet pressure.
Q: How to handle large fluctuations in outlet pressure? A: Check if the air supply is stable, if there are leaks in the pipeline, or if internal components are worn.
Q: How to resolve leakage from the regulator? A: Check if threaded connections are tight; reapply sealing tape if necessary. Inspect seals for damage and replace promptly.
Q: How to determine if the regulator requires maintenance? A: Maintenance should be performed when inaccurate pressure regulation, slow response, or abnormal noise is noticed.