WENK Pneumatic JMJ Mechanical Valve
Product Detail
Operating Media |
Air |
Working Pressure |
1~8kgf/cm² |
Proof Pressure |
12kgf/cm² |
Working Temperature Range |
-20℃~70℃ |
Body Material |
Aluminum Alloy |
JMJ Series Mechanical Valve User Manual

Product Overview
The JMJ Series Mechanical Valve is a high-performance manual directional control valve designed by WENK Pneumatic for precise airflow management in industrial pneumatic systems. Featuring a 2-position 3-way configuration, aluminum alloy body with NBR seals, this valve ensures durability and reliable operation in various industrial environments.
The JMJ Series offers multiple control head options including knob, button, roller, and lever types, providing flexible configuration for different application scenarios. With its compact design and easy installation, this valve is suitable for various automation equipment and industrial machinery.

Installation Steps
-
Confirm Installation Environment:
- Ensure the installation location is dry, clean, away from direct sunlight and high temperatures
- Reserve sufficient operating space for manual control and maintenance
-
Pipeline Preparation:
- Ensure connecting pipelines are clean, free of impurities and moisture
- Pipeline inner diameter should match the valve port size
-
Valve Installation:
- Use appropriate tools to install the valve in the designated position
- Ensure the valve is securely installed to avoid vibration and loosening
- Connect inlet and outlet pipes according to the flow direction markings on the valve body
-
Connection Check:
- Confirm all connections are tight and free from air leakage
- Check for twisted or excessively bent pipes
Confirm Installation Environment:
- Ensure the installation location is dry, clean, away from direct sunlight and high temperatures
- Reserve sufficient operating space for manual control and maintenance
Pipeline Preparation:
- Ensure connecting pipelines are clean, free of impurities and moisture
- Pipeline inner diameter should match the valve port size
Valve Installation:
- Use appropriate tools to install the valve in the designated position
- Ensure the valve is securely installed to avoid vibration and loosening
- Connect inlet and outlet pipes according to the flow direction markings on the valve body
Connection Check:
- Confirm all connections are tight and free from air leakage
- Check for twisted or excessively bent pipes

Operation Guide
-
Knob Type Operation:
- Rotate the knob to the desired position: Valve switches to the corresponding state
- Select different functional positions according to the markings
-
Button Type Operation:
- Press the button: Valve switches to working position
- Release the button: Valve resets (non-locking type) or maintains position (locking type)
- Locking type buttons require pressing again or rotating to unlock
-
Roller Type Operation:
- Activate the roller through external mechanical devices to switch the valve state
- Valve automatically returns to initial state after roller reset
-
Lever Type Operation:
- Move the lever: Valve switches to working position
- Release the lever: Valve automatically resets (spring return type)
-
Status Indication:
- Observe airflow status based on valve position changes
- Judge valve working status through the action of connected pneumatic components
Knob Type Operation:
- Rotate the knob to the desired position: Valve switches to the corresponding state
- Select different functional positions according to the markings
Button Type Operation:
- Press the button: Valve switches to working position
- Release the button: Valve resets (non-locking type) or maintains position (locking type)
- Locking type buttons require pressing again or rotating to unlock
Roller Type Operation:
- Activate the roller through external mechanical devices to switch the valve state
- Valve automatically returns to initial state after roller reset
Lever Type Operation:
- Move the lever: Valve switches to working position
- Release the lever: Valve automatically resets (spring return type)
Status Indication:
- Observe airflow status based on valve position changes
- Judge valve working status through the action of connected pneumatic components

Maintenance
-
Regular Inspection:
- Check valve connections weekly for tightness
- Monthly inspection of sealing performance to ensure no air leakage
- Quarterly comprehensive inspection including operational flexibility and appearance
-
Cleaning Maintenance:
- Keep valve surface clean, avoiding dust and debris accumulation
- Regularly clean the valve body, which can be purged with dry compressed air
-
Lubrication:
- No additional lubrication required, the valve interior is pre-lubricated
- Contact WENK Pneumatic technical support if increased operating resistance is noticed
Regular Inspection:
- Check valve connections weekly for tightness
- Monthly inspection of sealing performance to ensure no air leakage
- Quarterly comprehensive inspection including operational flexibility and appearance
Cleaning Maintenance:
- Keep valve surface clean, avoiding dust and debris accumulation
- Regularly clean the valve body, which can be purged with dry compressed air
Lubrication:
- No additional lubrication required, the valve interior is pre-lubricated
- Contact WENK Pneumatic technical support if increased operating resistance is noticed

Safety Warnings
- Ensure the air supply is cut off before installation
- Wear appropriate protective equipment during operation
- Do not use the valve for unintended purposes
- Regularly check the function of safety devices
- In case of serious failure, immediately cut off the air supply and contact WENK Pneumatic technical support