Leave Your Message
WENK Pneumatic KLCF Series-Union Straight
Products
Products Categories
Featured Products

WENK Pneumatic KLCF Series-Union Straight

The KLCF Series Quick Twist Union Straight from WENK Pneumatic is a premium brass fitting designed for efficient pneumatic system connections. Featuring a quick twist mechanism, this union straight enables fast and secure installation without additional tools, saving valuable time during assembly.

Constructed from high-quality brass, the KLCF Series offers excellent corrosion resistance and durability, ensuring reliable performance even in demanding industrial environments. The precision-engineered design guarantees a tight seal and optimal airflow, making it suitable for various pneumatic applications.

Ideal for connecting PU and other plastic tubes, the KLCF Series Quick Twist Union Straight provides a versatile solution for your pneumatic system needs. Available in multiple sizes (6mm, 8mm, 10mm, 12mm, 14mm) to accommodate different tube diameters and thread specifications, this fitting delivers consistent performance and long service life.

    Product Detail

    Applicable Fluid Compressed Air. (If liquid please ask for technical support)
    Proof Pressure 1.32MPa(13.5kgf/cm²)
    Max. Working Pressure 0~0.9MPa(0~9.2kgf/cm²)
    Vacuum -99.99~0KPa(-750~0kgf/cm²)
    Ambient & Fluid Temperature 0°C~+60°C
    Applicable Pipe PU Tube
    Material Brass

    KLCF Series Quick Twist Union Straight User Guide

    KLCF(1)

    Product Introduction

    The KLCF Series Quick Twist Union Straight is a high-quality brass fitting from WENK Pneumatic, designed specifically for pneumatic system connections. Featuring a quick twist mechanism, it enables tool-free installation and is suitable for connecting PU and other plastic tubes. The product offers excellent corrosion resistance and durability, ensuring reliable operation in various industrial environments.

    KLCF(2)

    Installation Steps

    1. Preparation

      • Ensure the installation environment is clean to prevent contaminants from entering the pneumatic system
      • Check that the tube is intact, without cracks or scratches
      • Select the appropriate size of KLCF Quick Twist Union to match the tube specifications
    2. Tube Preparation

      • Use a dedicated tube cutter to cut the tube to the required length
      • Ensure the tube end is clean and free of burrs or deformation
      • If the tube end is uneven, lightly sand it with fine-grit sandpaper
    3. Installation Process

      • Gently pull back the locking collar on the quick twist union with your fingers or a tool
      • Insert the prepared tube into the union's port until it cannot go further
      • Release the locking collar, ensuring it automatically resets and locks the tube in place
      • Gently pull the tube to confirm it is securely connected
    4. Connection Verification

      • After installation, perform a pressure test to ensure no leakage at the connection point
      • Inspect all connection points to ensure proper installation

    KLCF(3)

    Usage Precautions

    1. Operating Environment

      • Avoid using the product outside the specified temperature and pressure ranges
      • Not suitable for highly corrosive fluid environments unless specifically stated
      • Avoid prolonged exposure to direct sunlight and high-temperature environments
    2. Maintenance

      • Regularly inspect connection points to ensure no loosening or leakage
      • Keep the product clean to prevent dust and debris accumulation
      • If damage or abnormalities are found, replace the product promptly
    3. Safety Instructions

      • Ensure the system is depressurized before installation
      • Avoid excessive bending or stretching of connected tubes
      • Do not disassemble or modify the product arbitrarily

    KLCF(4)

    Troubleshooting

    1. Leakage Issues

      • Check if the tube is fully inserted into the port
      • Confirm the locking collar has properly reset
      • Inspect the tube for damage or uneven cutting
      • If the problem persists, replace the quick twist union
    2. Loose Connection

      • Verify that the tube specification matches the quick twist union
      • Check if the locking collar is damaged
      • Reinstall, ensuring the tube is fully inserted
    3. Restricted Airflow

      • Check for contaminants blocking the flow path
      • Ensure the tube is not bent or flattened
      • Verify that the system pressure is within the specified range

    KLCF_01

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset