Working Media |
Cleaned Air |
Working Pressure |
0.1~1Mpa |
Proof Pressure |
1Mpa |
Working Temperature Range |
0℃~80℃ |
Body Material |
Brass |
KTC Series Compression Fittings Straight Connector User Guide

Product Introduction
The KTC Series Compression Fitting Straight Connector is a high-quality pneumatic connection component manufactured by WENK Pneumatic. Made from premium H59 brass, it offers excellent corrosion resistance and long service life. This fitting is designed for straight connection of copper pipes in compressed air systems, forming a reliable seal through the compression action of the ferrule. It is suitable for copper, brass, and stainless steel pipes.

Installation Steps
-
Preparation
- Ensure the working environment is clean, free from dust and impurities
- Check that the fitting and pipe are intact and undamaged
- Prepare necessary tools: pipe cutter, deburring tool, torque wrench
-
Pipe Preparation
- Cut the pipe to the required length using a pipe cutter, ensuring a clean and perpendicular cut
- Use a deburring tool to remove burrs and sharp edges from both ends of the pipe
- Wipe the pipe surface with a clean cloth to ensure no oil or impurities
-
Fitting Installation
- Slide the nut and ferrule onto the pipe in sequence
- Fully insert the pipe into the bottom of the fitting body, ensuring it contacts the bottom step
- Hand-tighten the nut gently to ensure initial positioning of the ferrule
- Use a torque wrench to tighten the nut to the specified torque value (do not over-tighten)
-
Installation Inspection
- After installation, check if the pipe has any axial movement
- Check for any leakage at the connection point
- Perform a system pressure test to confirm the reliability of the connection
Preparation
- Ensure the working environment is clean, free from dust and impurities
- Check that the fitting and pipe are intact and undamaged
- Prepare necessary tools: pipe cutter, deburring tool, torque wrench
Pipe Preparation
- Cut the pipe to the required length using a pipe cutter, ensuring a clean and perpendicular cut
- Use a deburring tool to remove burrs and sharp edges from both ends of the pipe
- Wipe the pipe surface with a clean cloth to ensure no oil or impurities
Fitting Installation
- Slide the nut and ferrule onto the pipe in sequence
- Fully insert the pipe into the bottom of the fitting body, ensuring it contacts the bottom step
- Hand-tighten the nut gently to ensure initial positioning of the ferrule
- Use a torque wrench to tighten the nut to the specified torque value (do not over-tighten)
Installation Inspection
- After installation, check if the pipe has any axial movement
- Check for any leakage at the connection point
- Perform a system pressure test to confirm the reliability of the connection

Usage Instructions
-
Working Medium: Suitable for non-corrosive gases such as compressed air
-
Working Pressure: Use within the specified working pressure range
-
Working Temperature: The operating environment temperature should be between 0~80°C
-
Flow Control: Select the appropriate fitting size according to system requirements to ensure adequate flow
-
Regular Inspection: Periodically check connections for tightness and signs of leakage during use

Maintenance
-
Daily Inspection: Regularly check the fitting surface for corrosion, cracks, or other damage
-
Cleaning Maintenance: Keep the fitting surface clean to prevent dust and impurity accumulation
-
Seal Inspection: Check if the ferrule is intact, replace if necessary
-
Storage Requirements: Unused fittings should be stored in a dry, ventilated environment, avoiding direct sunlight and high temperatures

Troubleshooting
-
Leakage Issues
- Check if the nut is properly tightened
- Verify if the pipe is fully inserted
- Check if the ferrule is damaged, replace if necessary
-
Loose Connections
- Retighten the nut
- Check if the pipe is worn, replace if necessary
- Ensure the pipe size matches the fitting
-
Insufficient Flow
- Check if the fitting is clogged with impurities
- Confirm if the fitting size meets system flow requirements
- Verify if the system pressure is normal
Leakage Issues
- Check if the nut is properly tightened
- Verify if the pipe is fully inserted
- Check if the ferrule is damaged, replace if necessary
Loose Connections
- Retighten the nut
- Check if the pipe is worn, replace if necessary
- Ensure the pipe size matches the fitting
Insufficient Flow
- Check if the fitting is clogged with impurities
- Confirm if the fitting size meets system flow requirements
- Verify if the system pressure is normal

Our Commitments & Core Advantages
1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.