0102030405
WENK Pneumatic KtU Series Copper Locknut Double-Ended Straight Fittings
Product Detail
Working Media |
Cleaned Air |
Working Pressure |
0.1~1Mpa |
Proof Pressure |
1Mpa |
Working Temperature Range |
0℃~80℃ |
Body Material |
Brass |
KtU Series Copper Locknut Double-Ended Straight Fitting User Guide

Product Introduction
The KtU Series Copper Locknut Double-Ended Straight Fitting is a high-quality pneumatic connection component manufactured by WENK Pneumatic. Made from premium H59 brass with nickel plating, it offers excellent corrosion resistance and long service life. This fitting is designed for direct connection of two hoses with the same diameter in compressed air systems and is compatible with various hoses including PA, PU, and PE.

Installation Steps
-
Preparation
- Ensure the working environment is clean, free from dust and impurities
- Check that the fitting and hoses are intact and undamaged
- Prepare necessary tools: wrench, pipe cutter
-
Hose Preparation
- Cut both hoses to the required lengths using a pipe cutter, ensuring clean cuts
- Remove any burrs or debris from the inside of the hoses
- If the hoses are stiff, moderately heat the ends to facilitate insertion
-
Fitting Installation
- Unscrew the locknuts from both ends and slide them onto the respective hoses
- Fully insert both hoses into each end of the fitting body, ensuring they are properly seated
- Tighten the locknuts on both ends using a wrench (do not over-tighten)
- Check that both connections are secure and the hoses are not loose
-
System Testing
- After connection is complete, perform a system pressure test
- Check for any leakage at the connection points
- Confirm that airflow is smooth
Preparation
- Ensure the working environment is clean, free from dust and impurities
- Check that the fitting and hoses are intact and undamaged
- Prepare necessary tools: wrench, pipe cutter
Hose Preparation
- Cut both hoses to the required lengths using a pipe cutter, ensuring clean cuts
- Remove any burrs or debris from the inside of the hoses
- If the hoses are stiff, moderately heat the ends to facilitate insertion
Fitting Installation
- Unscrew the locknuts from both ends and slide them onto the respective hoses
- Fully insert both hoses into each end of the fitting body, ensuring they are properly seated
- Tighten the locknuts on both ends using a wrench (do not over-tighten)
- Check that both connections are secure and the hoses are not loose
System Testing
- After connection is complete, perform a system pressure test
- Check for any leakage at the connection points
- Confirm that airflow is smooth

Usage Instructions
-
Working Medium: Suitable for non-corrosive media such as compressed air, water, and oil
-
Working Pressure: Use within the specified working pressure range
-
Working Temperature: The operating environment temperature should be between 0~80°C
-
Flow Control: Select the appropriate fitting size according to system requirements to ensure adequate flow
-
Regular Inspection: Periodically check connections for tightness and signs of leakage during use

Maintenance
-
Daily Inspection: Regularly check the fitting surface for corrosion, cracks, or other damage
-
Cleaning Maintenance: Keep the fitting surface clean to prevent dust and impurity accumulation
-
Seal Inspection: Check if seals are aged or damaged, replace if necessary
-
Storage Requirements: Unused fittings should be stored in a dry, ventilated environment, avoiding direct sunlight and high temperatures

Troubleshooting
-
Leakage Issues
- Check if both locknuts are properly tightened
- Verify if the hoses are fully inserted
- Replace damaged seals
-
Loose Connections
- Retighten both locknuts
- Check if the hoses are worn, replace if necessary
- Ensure the hose size matches the fitting
-
Insufficient Flow
- Check if the fitting is clogged with impurities
- Confirm if the fitting size meets system flow requirements
- Verify if the system pressure is normal
Leakage Issues
- Check if both locknuts are properly tightened
- Verify if the hoses are fully inserted
- Replace damaged seals
Loose Connections
- Retighten both locknuts
- Check if the hoses are worn, replace if necessary
- Ensure the hose size matches the fitting
Insufficient Flow
- Check if the fitting is clogged with impurities
- Confirm if the fitting size meets system flow requirements
- Verify if the system pressure is normal

Our Commitments & Core Advantages
1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.