WENK Pneumatic LR Series Filter Regulator
Product Detail
| Model | Mini | Midi | Maxi | |||||||
| Port Size | G1/8 | G1/4 | G3/8 | G1/4 | G3/8 | G1/2 | G3/4 | G1/2 | G3/4 | G1 |
| Structural Features | Direct-Operated Diaphragm Pressure Regulator | Pilot-Operated Piston | ||||||||
| Direct-Operated | ||||||||||
| Operating Media | Filtered Compressed Air,Filtration Grade: 40μm | |||||||||
| Input Pressure | 1 bar~16 bar | |||||||||
| Maximum Hysteresis | 0.2 bar | 0.4 bar | ||||||||
| Adjustment Range | 0.5 bar~7 bar / 0.5 bar~12 bar | |||||||||
| Material | Aluminum Alloy / Zinc Alloy | |||||||||
Festo LR Series Pressure Regulator - User Guide

Product Overview
The Festo LR series pressure regulator is a high-end Festo-type air preparation unit featuring a direct-acting diaphragm design. It provides precise and stable pressure control for pneumatic systems. Through main pressure compensation, it maintains constant output pressure despite fluctuations in input pressure, ensuring stable operation of pneumatic components.
Technical Parameters:
- Type: Direct-acting diaphragm pressure regulator
- Operating pressure: 1-16 bar
- Pressure regulation range: 0.5-7 bar or 0.5-12 bar
- Flow range: 120-12500 l/min
- Operating temperature: -10-60°C
- Maximum pressure hysteresis: 0.2-0.4 bar
- Connection size: G1/8 to G1
- Design features: With secondary venting, metal housing, NBR seals
- Mounting: Pipe mounting or panel mounting
- Features: Precise pressure control, main pressure compensation, secondary venting, optional locking device, multiple sizes available

Installation Steps
1. Pre-installation Preparation
- Ensure the compressed air system is shut off and depressurized
- Clean connecting pipes to remove foreign objects and impurities
- Prepare necessary tools: wrench, PTFE tape, etc.
- Inspect the pressure regulator for damage and confirm the model meets system requirements
2. Installation Position and Sequence
- Installation sequence: In a pneumatic system, the pressure regulator should be installed after the filter
- Installation position: Should be installed in a horizontal or vertical position, avoiding inclined installation
- Installation direction: Must be installed according to the airflow direction marked on the valve body
3. Pipe Connection
- Use PTFE tape for thread sealing (note: do not allow PTFE tape to enter the pipe interior)
- Tighten connections evenly with a wrench, avoiding excessive force that may damage threads
- Ensure all connections are secure and tight without leakage
4. Mounting Installation
- Pipe mounting: Directly fixed through pipe connections
-
Panel mounting:
- Drill a 36.5mm diameter mounting hole in the panel
- Insert the pressure regulator into the mounting hole
- Secure with the dedicated fixing nut from the back of the panel
- Ensure secure installation without looseness
5. Pressure Gauge Installation (Optional)
- Install pressure gauge using G1/8 connection
- Ensure the pressure gauge is securely installed and the reading is clearly visible
- The pressure gauge range should match the regulator's pressure regulation range
6. Post-installation Check
- Ensure all connections are secure without looseness
- Confirm airflow direction matches the arrow indication
- Check if the installation position meets requirements
- Verify that the locking device (if equipped) functions properly

Operation Guide
1. Initial Pressure Setting
-
Pressure adjustment method:
- Rotate the adjustment knob counterclockwise to the minimum pressure position
- Slowly open the air supply and observe the pressure gauge reading
- Rotate the adjustment knob clockwise to adjust the pressure to the desired value
- After adjustment, if equipped with a locking device, lock the current setting
-
Precautions:
- Adjust slowly to avoid sudden pressure increases
- The set pressure should not exceed the system requirements
- The set pressure should not exceed the regulator's maximum adjustment range
2. Pressure Adjustment Operation
- Increase pressure: Rotate the adjustment knob clockwise
- Decrease pressure: Rotate the adjustment knob counterclockwise
- Pressure locking: If equipped with a locking device, press or rotate the locking mechanism after adjustment
3. Operation Check
- After starting the system, observe the operation of the pressure regulator
- Check if the output pressure is stable at the set value
- Inspect all connections for leaks
- Confirm the secondary venting function is normal (gas should be exhausted when reducing pressure)

Maintenance
1. Daily Inspection
- Regularly check if the output pressure is stable
- Verify if the pressure gauge reading is accurate
- Inspect all connections for leaks
- Keep the valve body clean, avoiding dust and debris accumulation
2. Periodic Maintenance
-
Cleaning and maintenance:
- Shut off the air supply and release system pressure
- Disassemble the pressure regulator (if necessary)
- Clean the exterior of the valve body with compressed air
- Inspect the condition of diaphragms and seals
- Reinstall and test
-
Maintenance cycle:
- Daily inspection: Once a week
- Cleaning maintenance: Once every 3 months
- Seal replacement: Once every 12 months or as needed
- Comprehensive inspection: Once every 12 months
3. Troubleshooting
-
Unstable output pressure:
- Check if the input pressure is stable
- Inspect if the diaphragm is damaged
- Check if the valve seat has impurities
- Inspect if the adjustment spring is fatigued
-
Unable to reach set pressure:
- Check if the input pressure is sufficient
- Verify if the adjustment range matches requirements
- Check if the valve port is blocked
- Inspect if the diaphragm is damaged
-
Pressure leakage:
- Check if connections are tight
- Inspect if seals are damaged
- Check if the valve body has cracks
- Inspect if the pressure gauge interface is leaking

Precautions
1. Safety Precautions
- Always shut off the air supply and release pressure before installation and maintenance
- Do not exceed the maximum working pressure of 16 bar
- Avoid use in high-temperature environments (temperature not exceeding 60°C)
- Do not strike or scratch the valve body with sharp objects
2. Usage Limitations
- For compressed air systems only
- Not suitable for corrosive gas environments
- Avoid direct sunlight and strong vibration
- Not for use with oxygen or other flammable and explosive gases
3. Repair and Replacement
- Use original accessories for maintenance
- Follow product manual guidelines for seal replacement
- If valve body damage is found, immediately stop use and replace
- Conduct pressure testing after maintenance to ensure safety

Frequently Asked Questions
Q1: Where should the pressure regulator be installed in a pneumatic system?
A1: The pressure regulator should be installed after the filter, near the pneumatic components requiring stable pressure.
Q2: How to determine if the pressure regulator is working properly?
A2: After starting the system, observe if the pressure gauge reading remains stable at the set value and if the pressure adjustment responds sensitively.
Q3: Can the pressure regulator be adjusted while the system is running?
A3: Yes, the LR series pressure regulator is designed to allow pressure adjustment during system operation.
Q4: What is the recommended maintenance cycle?
A4: Daily inspection once a week, cleaning maintenance once every 3 months, and seal replacement once every 12 months.
Q5: What may cause unstable output pressure of the regulator?
A5: Possible causes include: input pressure fluctuations, damaged diaphragm, impurities on the valve seat, or fatigued adjustment spring.