Leave Your Message
WENK Pneumatic MXQ Series Pneumatic Slide Table
Products
Products Categories
Featured Products

WENK Pneumatic MXQ Series Pneumatic Slide Table

The MXQ series pneumatic slide table is a high-precision linear motion device designed for automated applications requiring exceptional rigidity and accuracy. Featuring a compact, integrated design with hardened stainless steel recirculating linear guides, this slide table delivers outstanding parallelism and perpendicularity with repeatable positioning accuracy of ±0.05mm.

Available in bore sizes from 6mm to 25mm with strokes ranging from 10mm to 150mm, the MXQ slide table offers versatile solutions for space-constrained installations. Its double-acting design ensures reliable bidirectional movement, while the integrated shock absorbers provide smooth end-of-stroke cushioning.

Engineered for efficiency, this slide table operates at pressures between 0.15MPa and 0.7MPa, with a temperature range of -10°C to 60°C. The optional end lock feature prevents dropping in vertical applications, enhancing safety. Suitable for various industrial applications including precision assembly, material handling, and automated testing, the MXQ pneumatic slide table delivers consistent performance in a streamlined design.

    Product Detail

    Bore 6 8 12 16 20 25
    Port Size M5x0.8 Rc1/8
    Actuation Method Double-Acting
    Operating Pressure 0.15~0.7Mpa
    Ambient Temperature -10℃~60℃
    Operating Piston Speed 50~500mm/s
    Material Aluminum Alloy

    MXQ Pneumatic Slide Table User Manual

    MXQ(1)

    1. Product Introduction

    The MXQ series pneumatic slide table is a high-precision linear motion device designed specifically for automated applications requiring exceptional rigidity and accuracy. Featuring a hardened stainless steel recirculating linear guide system, it provides excellent parallelism and perpendicularity with repeatable positioning accuracy of ±0.05mm.

    Product Features

    • Compact design, saving installation space
    • Hardened stainless steel recirculating linear guide for high rigidity and precision
    • Double-acting design with bidirectional force output
    • Integrated buffer device for smooth operation and low noise
    • Multi-directional piping options for flexible installation
    • Proximity switch mountable for precise position detection
    • Optional end lock feature to prevent dropping in vertical applications
    • Multiple bore sizes and strokes available to meet different application requirements
    MXQ(2)

    2. Technical Parameters

    Basic Parameters

    • Action type: Double-acting
    • Operating medium: Compressed air (filtered to 40μm or finer)
    • Operating pressure range: 0.15-0.7MPa
    • Pressure resistance: 1.05MPa
    • Ambient and fluid temperature: -10~60°C (non-freezing)
    • Piston speed: 50~500mm/s (with buffer)
    • Lubrication method: Non-lube

    Specifications

    • Bore size: 6, 8, 12, 16, 20, 25mm
    • Stroke: 10, 20, 30, 40, 50, 75, 100, 125, 150mm
      • Maximum stroke for 6mm bore: 50mm
      • Maximum stroke for 8mm bore: 75mm
      • Maximum stroke for 12mm and above: 150mm
    • Connection size: M5×0.8
    • Repeat positioning accuracy: ±0.05mm
    MXQ(3)

    3. Installation Steps

    Pre-installation Preparation

    1. Confirm that the slide table model matches the installation environment
    2. Check if the slide table appearance is intact and undamaged
    3. Prepare necessary installation tools and accessories
    4. Ensure the installation surface is flat and clean

    Installation Process

    1. Select appropriate mounting accessories based on the installation method
    2. Fix the slide table in the installation position, ensuring the slide movement direction is aligned with the load movement direction
    3. Connect the air supply pipeline, choosing the convenient piping direction from multiple options
    4. Install the magnetic switch (if any) and adjust to the appropriate position
    5. If installing the end lock device, ensure proper compatibility with the slide table
    6. Check that all connections are secure and without looseness

    Installation Precautions

    • Avoid excessive radial load and moment on the slide table
    • Ensure coaxiality between the slide table and the load during installation
    • Reserve sufficient buffer space to avoid collision
    • Ensure correct pipeline connection without leakage
    • Always use the end lock function for vertical installations
    • Maintain appropriate spacing when installing multiple slide tables side by side
    MXQ(4)

    4. Operation Guide

    Pre-operation Check

    1. Confirm that the air supply pressure is within the specified range
    2. Check that all connections are secure
    3. Ensure the working environment is clean with no impurities entering the slide table
    4. If using the end lock function, confirm its proper operation

    Operation Procedure

    1. Slowly open the air supply valve to make the slide table move slowly
    2. Observe if the slide table operates smoothly without abnormal noise
    3. Test the working status of the magnetic switch (if any)
    4. Test the end lock function (if any) to ensure reliable locking in case of pressure loss
    5. Adjust the working pressure and flow as needed

    Operation Precautions

    • Avoid using beyond the rated pressure
    • Avoid long-term high-speed operation of the slide table without lubrication
    • Do not strike the slide table body and piston rod
    • Regularly check the slide table operation status and stop for inspection if abnormalities are found
    • Avoid adjusting or disassembling components while the slide table is in operation
    • Always activate the end lock function for vertical applications
    MXQ(5)

    5. Maintenance

    Daily Maintenance

    1. Keep the slide table exterior clean
    2. Check if the air supply pressure is stable
    3. Check for leaks at connection points
    4. Listen to the operating sound to determine if it is normal

    Regular Maintenance

    1. Weekly inspection:

      • Slide table operation status
      • Fastening condition of connection parts
      • Magnetic switch working status
      • Reliability of end lock function (if any)
    2. Monthly inspection:

      • Piston rod and guide rail surface condition
      • Buffering effect
      • Seal condition
    3. Quarterly inspection:

      • Internal condition of the slide table
      • Replace worn seals
      • Comprehensive slide table cleaning

    Maintenance Precautions

    • Use recommended lubricants
    • Avoid using corrosive cleaning agents
    • Ensure the air supply is turned off during maintenance
    • Pay attention to model matching when replacing seals
    • Use a clean soft cloth when cleaning the guide rail to avoid scratching the surface
    • Regularly check the reliability of the end lock device
    MXQ(1)

    6. Troubleshooting

    1. Slide table does not operate

      • Possible causes:
        • Insufficient air supply pressure
        • Solenoid valve failure
        • Airway blockage
        • Damaged seals
        • End lock not released (if equipped)
      • Solutions:
        • Check air supply pressure and adjust to the specified range
        • Check solenoid valve working status, replace if necessary
        • Clean the airway to ensure smooth flow
        • Inspect seals and replace if necessary
        • Check the end lock device to ensure it is properly released
    2. Slide table moves slowly or weakly

      • Possible causes:
        • Insufficient air supply pressure
        • Insufficient flow
        • Worn piston or piston rod seals
        • Insufficient lubrication or contamination of guide rail
      • Solutions:
        • Increase air supply pressure
        • Increase pipe diameter or reduce pipe length
        • Replace seals
        • Clean the guide rail and add appropriate lubricant
    3. Slide table operates unsteadily or with abnormal noise

      • Possible causes:
        • Improper adjustment of buffer device
        • Insufficient lubrication
        • Contaminated or damaged guide rail
        • Excessive load or improper installation
      • Solutions:
        • Adjust the buffer device
        • Increase lubrication
        • Clean or replace the guide rail
        • Check load and installation conditions, reinstall if necessary
    4. Air leakage

      • Possible causes:
        • Worn or damaged seals
        • Loose connection parts
        • Damaged cylinder barrel or piston rod
      • Solutions:
        • Replace seals
        • Tighten connection parts
        • Inspect cylinder barrel and piston rod, replace if necessary
    5. Magnetic switch does not work

      • Possible causes:
        • Improper switch installation position
        • Switch failure
        • Insufficient magnet strength
      • Solutions:
        • Adjust switch position
        • Check switch circuit, replace if necessary
        • Contact supplier to check magnet strength
    6. End lock function failure (if equipped)

      • Possible causes:
        • Insufficient end lock air pressure
        • Damaged end lock mechanism
        • Mechanical jamming
      • Solutions:
        • Check if the end lock air pressure is normal
        • Inspect the end lock mechanism, replace if necessary
        • Clean the end lock mechanism to eliminate jamming
    MXQ气动滑台MXQ_1MXQ_2MXQ_3MXQ_4MXQ_5MXQ_6

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset