Leave Your Message
WENK Pneumatic MXS Series Pneumatic Slide Table
Products
Products Categories
Featured Products

WENK Pneumatic MXS Series Pneumatic Slide Table

The MXS series pneumatic slide table is a high-precision linear motion device designed for automated applications requiring exceptional rigidity and accuracy. Featuring an integrated cross roller bearing system with dual air cylinders, this slide table delivers outstanding parallelism and perpendicularity with smooth, backlash-free movement.

Available in bore sizes from 6mm to 25mm with strokes ranging from 10mm to 150mm, the MXS slide table offers versatile solutions for space-constrained installations. Its compact design combines the functionality of a precision guide and dual cylinders, providing twice the output force of conventional single-cylinder designs.

Engineered for efficiency, this slide table operates at pressures between 0.15MPa and 0.7MPa, with a temperature range of -10°C to 60°C. Optional features include stroke adjusters, shock absorbers, and end locks for vertical applications. Suitable for precision assembly, material handling, and automated testing, the MXS pneumatic slide table delivers reliable performance in a streamlined package.

    Product Detail

    Bore 6 8 12 16 20 25
    Port Size M3x0.8 M5x0.8 Rc1/8 | NPT1/8 | G1/8
    Actuation Method Double-Acting
    Operating Pressure 0.15~0.7Mpa
    Ambient Temperature -10℃~60℃
    Operating Piston Speed 50~500mm/s
    Material Aluminum Alloy

    MXS Pneumatic Slide Table User Manual

    MXS(1)

    1. Product Introduction

    The MXS series pneumatic slide table is a high-precision linear motion device designed specifically for automated applications requiring exceptional rigidity and accuracy. Featuring an integrated cross roller bearing system with dual air cylinders, it provides excellent parallelism and perpendicularity with smooth, backlash-free movement.

    Product Features

    • Compact design with integrated table and cylinder, saving installation space
    • Cross roller guide system for high rigidity, precision, and backlash-free operation
    • Dual-cylinder construction delivering twice the output force of conventional single-cylinder designs
    • Integrated buffer device for smooth operation and low noise
    • Multi-directional piping options for flexible installation
    • Proximity switch mountable for precise position detection
    • Optional end lock feature to prevent dropping in vertical applications
    • Multiple bore sizes and strokes available to meet different application requirements
    • Optional clean room specification (contamination grade 3) for clean environment applications
    MXS(2)

    2. Technical Parameters

    Basic Parameters

    • Action type: Double-acting
    • Operating medium: Compressed air (filtered to 40μm or finer)
    • Operating pressure range: 0.15-0.7MPa
    • Pressure resistance: 1.05MPa
    • Ambient and fluid temperature: -10~60°C (non-freezing)
    • Piston speed: 50~500mm/s (with buffer)
    • Lubrication method: Non-lube

    Specifications

    • Bore size: 6, 8, 12, 16, 20, 25mm
    • Stroke: 10, 20, 30, 40, 50, 75, 100, 125, 150mm
    • Connection size: M5×0.8
    • Repeat positioning accuracy: ±0.05mm
    • Theoretical thrust at 0.7MPa:
      • 6mm bore: 53N
      • 8mm bore: 94N
      • 12mm bore: 212N
      • 16mm bore: 281N
      • 20mm bore: 439N
      • 25mm bore: 686N
    MXS(3)

    3. Installation Steps

    Pre-installation Preparation

    1. Confirm that the slide table model matches the installation environment
    2. Check if the slide table appearance is intact and undamaged
    3. Prepare necessary installation tools and accessories
    4. Ensure the installation surface is flat and clean

    Installation Process

    1. Select appropriate mounting accessories based on the installation method
    2. Fix the slide table in the installation position, ensuring the slide movement direction is aligned with the load movement direction
    3. Connect the air supply pipeline, choosing the convenient piping direction from multiple options
    4. Install the magnetic switch (if any) and adjust to the appropriate position
    5. If installing the end lock device, ensure proper compatibility with the slide table
    6. Check that all connections are secure and without looseness

    Installation Precautions

    • Avoid excessive radial load and moment on the slide table
    • Ensure coaxiality between the slide table and the load during installation
    • Reserve sufficient buffer space to avoid collision
    • Ensure correct pipeline connection without leakage
    • Always use the end lock function for vertical installations
    • Maintain appropriate spacing when installing multiple slide tables side by side
    • For clean room installation, ensure all components meet cleanliness requirements
    MXS(4)

    4. Operation Guide

    Pre-operation Check

    1. Confirm that the air supply pressure is within the specified range
    2. Check that all connections are secure
    3. Ensure the working environment is clean with no impurities entering the slide table
    4. If using the end lock function, confirm its proper operation

    Operation Procedure

    1. Slowly open the air supply valve to make the slide table move slowly
    2. Observe if the slide table operates smoothly without abnormal noise
    3. Test the working status of the magnetic switch (if any)
    4. Test the end lock function (if any) to ensure reliable locking in case of pressure loss
    5. Adjust the working pressure and flow as needed

    Operation Precautions

    • Avoid using beyond the rated pressure
    • Avoid long-term high-speed operation of the slide table without lubrication
    • Do not strike the slide table body and piston rod
    • Regularly check the slide table operation status and stop for inspection if abnormalities are found
    • Avoid adjusting or disassembling components while the slide table is in operation
    • Always activate the end lock function for vertical applications
    • For clean room use, prevent contaminants from entering the slide table interior
    MXS(5)

    5. Maintenance

    Daily Maintenance

    1. Keep the slide table exterior clean
    2. Check if the air supply pressure is stable
    3. Check for leaks at connection points
    4. Listen to the operating sound to determine if it is normal

    Regular Maintenance

    1. Weekly inspection:

      • Slide table operation status
      • Fastening condition of connection parts
      • Magnetic switch working status
      • Reliability of end lock function (if any)
    2. Monthly inspection:

      • Piston rod and guide rail surface condition
      • Buffering effect
      • Seal condition
    3. Quarterly inspection:

      • Internal condition of the slide table
      • Replace worn seals
      • Comprehensive slide table cleaning
    MXS(1)

    6. Safety Precautions

    • Always turn off the air supply before installation and maintenance
    • Avoid sudden start or stop of the slide table to prevent impact
    • Do not disassemble or adjust while the slide table is working
    • Avoid overloading the slide table
    • Must use the end lock function for vertical installations
    • Regularly check safety protection devices
    • Operators should be familiar with this user manual
    • For clean room use, follow clean room safety operating procedures
    MXS气动滑台MXS_1MXS_2MXS_3MXS_4MXS_5MXS_6

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset