0102030405
WENK Pneumatic RE Series Flow Control Valve
Product Detail
Working Media |
Cleaned Air |
Max.Operating Pressure |
0.8Mpa |
Proof Pressure |
1.0Mpa |
Working Temperature Range |
0℃~70℃ |
Body Material |
Aluminum Alloy |
RE Flow Control Valve User Guide

1. Product Introduction
The RE Flow Control Valve is a high-precision pneumatic control component developed by WENK Pneumatic, designed specifically for air flow regulation in industrial systems. Featuring a robust black body, brass connection ports, and a chrome-plated adjustment knob, this product ensures reliable performance in various industrial environments. The RE-04 model has a working pressure range of 1.5-8 kgf/cm², suitable for pneumatic circuits requiring precise speed and flow management, widely used in manufacturing and automation fields.
Main features:
- Robust black body design
- High-quality brass connection ports
- Chrome-plated adjustment knob for easy operation
- Working pressure range: 1.5-8 kgf/cm²
- Precise flow control performance
- Suitable for various industrial pneumatic systems

2. Installation Instructions
2.1 Pre-installation Preparation
- Ensure the installation environment meets the product working conditions
- Check that the product packaging is intact and undamaged
- Prepare necessary installation tools and accessories
- Confirm the air flow direction, the valve body is marked with P (inlet) and A (outlet)
2.2 Installation Steps
- Shut off the air supply to ensure safety during installation
- Install the valve body in the pneumatic circuit according to the air flow direction
- Use appropriate tools to connect the inlet port (P) to the air source
- Connect the outlet port (A) to the equipment requiring flow control
- Use sealing tape or sealant to ensure tight connections and prevent air leakage
- Check all connections for firmness
2.3 Installation Notes
- Avoid strong impact to the valve body during installation
- Ensure correct connection of inlet and outlet ports, avoid reverse installation
- Installation environment should avoid high temperature, humidity, and corrosive gases
- Regularly check the tightness of installation connections

3. Usage Methods
3.1 Pre-operation Check
- Confirm that the air source pressure is within the 1.5-8 kgf/cm² range
- Check that all connections are firm and free from air leakage
- Test the flexibility of the adjustment knob
3.2 Flow Adjustment
- Rotate the adjustment knob clockwise to decrease flow
- Rotate the adjustment knob counterclockwise to increase flow
- Gradually adjust to the required flow according to system requirements
- After adjustment is complete, the position can be locked using the nut on top of the knob
3.3 Operation Notes
- Avoid excessive rotation of the adjustment knob, which may cause damage to internal parts
- Adjustments should be made slowly to avoid sudden changes in system pressure
- If abnormal sounds or resistance are found, stop using immediately and inspect
- When not in use for a long time, it is recommended to turn off the air source

4. Maintenance
4.1 Daily Maintenance
- Regularly clean the valve body surface to remove dust and oil
- Check the flexibility of the adjustment knob
- Test the accuracy of flow control
4.2 Regular Inspection
- Check the sealing status of connection ports monthly
- Inspect the wear condition of internal seals quarterly
- Perform a comprehensive cleaning and lubrication every six months
4.3 Maintenance Notes
- Use neutral detergent for cleaning, avoid using corrosive solvents
- Use special pneumatic component lubricating oil for lubrication
- Ensure the air source is turned off during maintenance to avoid accidental activation
- If parts need to be replaced, it is recommended to use original accessories

5. Troubleshooting
-
Flow cannot be adjusted
- Adjustment knob stuck: Clean and lubricate the adjustment mechanism
- Internal parts damaged: Replace damaged parts
-
Air leakage
- Loose connections: Reconnect and reinforce
- Seal wear: Replace seals
-
Inaccurate flow control
- Internal contamination: Clean internal flow passages
- Part wear: Replace worn parts
Flow cannot be adjusted
- Adjustment knob stuck: Clean and lubricate the adjustment mechanism
- Internal parts damaged: Replace damaged parts
Air leakage
- Loose connections: Reconnect and reinforce
- Seal wear: Replace seals
Inaccurate flow control
- Internal contamination: Clean internal flow passages
- Part wear: Replace worn parts

Our Commitments & Core Advantages
1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.