WENK Pneumatic S-AS Push-to-Lock Elbow Type Speed Control Valve
Product Detail
Working Media |
Cleaned Air |
Working Pressure |
0.1~1Mpa |
Proof Pressure |
1.5Mpa |
Working Temperature Range |
0℃~60℃ |
Body Material |
Plastic |
WENK Pneumatic S-AS Push-Lock Elbow Speed Control Valve User Guide

1. Product Introduction
The S-AS Push-Lock Elbow Speed Control Valve is a high-precision pneumatic flow control component developed by WENK Pneumatic, specifically designed for cylinder speed regulation in industrial automation systems.
Main Features:
- Push-lock design allows flow setting and locking without tools
- Elbow structure design saves installation space, suitable for compact environments
- High-quality brass valve body (with electrolytic nickel plating) and PBT engineering plastic knob
- Compatible with various tube materials: nylon, soft nylon, polyurethane, etc.
- Operating temperature range: 0°C to 60°C
- Operating pressure range: 0.1 to 1.0 MPa

2. Working Principle
The S-AS Speed Control Valve regulates cylinder operating speed by adjusting the size of the gas flow cross-section. Its internal structure includes:
- Valve Body: The main part connecting the tube and cylinder
- Throttle Column: Adjusts its position through the knob, changing the gas flow cross-section
- Check Valve: Ensures one-way gas flow, enabling independent control of cylinder extension and retraction speeds
- Push-Lock Mechanism: Fixes the throttle column position to prevent setting loosening
When the knob is rotated, the throttle column moves up and down, changing the cross-sectional area through which gas passes, thereby controlling gas flow and ultimately adjusting the cylinder's operating speed. The push-lock mechanism ensures that the set flow value remains stable in vibrating environments.

3. Installation Guide
Preparation Before Installation:
- Confirm that the product model matches the application requirements
- Check if the product is damaged
- Prepare necessary tools and tubing
Installation Steps:
-
Tube Preparation:
- Ensure the cut is perpendicular and smooth when cutting the tube
- Remove burrs from the tube port
- Measure the required tube length, leaving appropriate allowance
-
Connecting the Tube:
- Press the release collar
- Insert the tube into the fitting until it can no longer be pushed forward
- Release the collar to ensure the tube is firmly clamped
-
Thread Connection:
- Apply appropriate sealant or use Teflon tape on the threaded part
- Use suitable tools to connect the valve to the cylinder or other pneumatic components
- Be careful not to overtighten to avoid damaging the threads
-
Installation Direction:
- The arrow on the valve body indicates the gas flow direction
- Ensure the installation direction is consistent with the actual air flow direction
- The elbow design allows 360° rotation, which can be adjusted according to space requirements
Tube Preparation:
- Ensure the cut is perpendicular and smooth when cutting the tube
- Remove burrs from the tube port
- Measure the required tube length, leaving appropriate allowance
Connecting the Tube:
- Press the release collar
- Insert the tube into the fitting until it can no longer be pushed forward
- Release the collar to ensure the tube is firmly clamped
Thread Connection:
- Apply appropriate sealant or use Teflon tape on the threaded part
- Use suitable tools to connect the valve to the cylinder or other pneumatic components
- Be careful not to overtighten to avoid damaging the threads
Installation Direction:
- The arrow on the valve body indicates the gas flow direction
- Ensure the installation direction is consistent with the actual air flow direction
- The elbow design allows 360° rotation, which can be adjusted according to space requirements

4. Usage Instructions
Speed Adjustment:
-
Unlock: Pull the knob upward to release the locked state
-
Adjust:
- Rotate the knob clockwise: reduce flow, decrease cylinder speed
- Rotate the knob counterclockwise: increase flow, increase cylinder speed
-
Lock: After adjustment, press the knob downward until a "click" sound is heard to confirm locking
- Rotate the knob clockwise: reduce flow, decrease cylinder speed
- Rotate the knob counterclockwise: increase flow, increase cylinder speed
Usage Recommendations:
- For initial adjustment, it is recommended to start from the minimum flow and gradually increase to the required speed
- Avoid removing the tube under system pressure to prevent accidental ejection
- Regularly check connection parts for leaks
- Adjust the maintenance cycle appropriately according to environmental conditions
Precautions:
- Do not exceed the maximum working pressure and temperature range
- Avoid installing the valve in direct sunlight or high-temperature environments
- Do not use compressed air containing corrosive substances
- Regularly drain condensate from the system

5. Troubleshooting
Common Problems and Solutions:
-
Cylinder Speed Cannot Be Adjusted
- Check if unlocked: Confirm the knob has been fully pulled upward
- Check if the throttle hole is blocked: Clean the throttle hole
- Check if the supply pressure is stable: Ensure the pressure is within the working range
-
Flow Setting Changes Automatically
- Check the locking mechanism: Confirm the knob has been fully pressed and locked
- Check if the working environment vibration is too large: Add vibration reduction measures if necessary
- Check if there is external force collision: Readjust and lock
-
Leakage Problems
- Check tube connection: Ensure the tube is fully inserted into the fitting
- Check thread connection: Reapply sealant and tighten appropriately
- Check if the seal is damaged: Replace the seal if necessary
-
Insensitive Adjustment
- Check if there are impurities in the throttle hole: Clean the throttle hole
- Check if the gas is clean: Install a filter
- Check if the valve interior is worn: Replace the valve if necessary
Cylinder Speed Cannot Be Adjusted
- Check if unlocked: Confirm the knob has been fully pulled upward
- Check if the throttle hole is blocked: Clean the throttle hole
- Check if the supply pressure is stable: Ensure the pressure is within the working range
Flow Setting Changes Automatically
- Check the locking mechanism: Confirm the knob has been fully pressed and locked
- Check if the working environment vibration is too large: Add vibration reduction measures if necessary
- Check if there is external force collision: Readjust and lock
Leakage Problems
- Check tube connection: Ensure the tube is fully inserted into the fitting
- Check thread connection: Reapply sealant and tighten appropriately
- Check if the seal is damaged: Replace the seal if necessary
Insensitive Adjustment
- Check if there are impurities in the throttle hole: Clean the throttle hole
- Check if the gas is clean: Install a filter
- Check if the valve interior is worn: Replace the valve if necessary