WENK Pneumatic SCQ-06 Barb-Barb
Product Detail
Working Media |
Cleaned Air |
Working Pressure |
0.1~1Mpa |
Proof Pressure |
1.5Mpa |
Working Temperature Range |
0℃~80℃ |
Body Material |
Brass |
SCQ-06 Double-Barb Ball Valve User Guide

Product Introduction
The SCQ-06 Double-Barb Ball Valve is a high-quality brass valve manufactured by WENK Pneumatic, specifically designed for hose connections in pneumatic and fluid systems. Both ends of the valve feature barb-type interfaces that can securely connect various hoses including silicone, PU, PVC, and rubber hoses. The product is made of premium brass material, offering excellent pressure resistance and corrosion resistance, suitable for air compressors, plumbing, industrial pneumatic, and various other applications.

Installation Instructions
-
Preparation:
- Ensure the inner diameter of the hose matches the valve's barb interface size
- Clean the hose ends to ensure no burrs or impurities
- Prepare hose clamps for securing the hoses
-
Installation Steps:
- Slide one end of the hose onto the valve's barb interface, ensuring it is fully inserted
- Use hose clamps to secure the connection between the hose and barb interface, ensuring a firm connection
- Connect the other end of the hose using the same method
- Check all connection points for firmness and ensure no leakage
Preparation:
- Ensure the inner diameter of the hose matches the valve's barb interface size
- Clean the hose ends to ensure no burrs or impurities
- Prepare hose clamps for securing the hoses
Installation Steps:
- Slide one end of the hose onto the valve's barb interface, ensuring it is fully inserted
- Use hose clamps to secure the connection between the hose and barb interface, ensuring a firm connection
- Connect the other end of the hose using the same method
- Check all connection points for firmness and ensure no leakage

Usage Instructions
-
Opening/Closing Operation:
- Rotate the handle clockwise to the vertical position for the closed state
- Rotate the handle counterclockwise to the horizontal position for the open state
- Operate with smooth rotation, avoiding excessive force
-
Flow Regulation:
- Flow can be adjusted by rotating the handle to different angles
- Flow is maximum when the handle is parallel to the pipe, and zero when perpendicular
Opening/Closing Operation:
- Rotate the handle clockwise to the vertical position for the closed state
- Rotate the handle counterclockwise to the horizontal position for the open state
- Operate with smooth rotation, avoiding excessive force
Flow Regulation:
- Flow can be adjusted by rotating the handle to different angles
- Flow is maximum when the handle is parallel to the pipe, and zero when perpendicular

Maintenance
-
Regular Inspection:
- Regularly check the valve for any leakage
- Check if the handle operates flexibly, handle any jamming promptly
- Check if hose connections are secure and if clamps are loose
-
Cleaning and Lubrication:
- Keep the valve surface clean, avoid accumulation of dust and impurities
- For valves in long-term use, regularly add a small amount of lubricating oil to the handle rotation shaft
Regular Inspection:
- Regularly check the valve for any leakage
- Check if the handle operates flexibly, handle any jamming promptly
- Check if hose connections are secure and if clamps are loose
Cleaning and Lubrication:
- Keep the valve surface clean, avoid accumulation of dust and impurities
- For valves in long-term use, regularly add a small amount of lubricating oil to the handle rotation shaft

Troubleshooting
-
Leakage Issues:
- Check if the hose is fully inserted into the barb interface
- Check if hose clamps are loose, retighten if necessary
- Check if the hose is aged or damaged, replace if problems are found
-
Handle Operation Inflexibility:
- Check if there are foreign objects stuck in the handle rotation shaft
- If jamming is caused by rust, add lubricating oil and switch the valve multiple times
- If the problem is severe, replacement of the valve is recommended
-
Abnormal Flow:
- Check if the valve interior is blocked by impurities
- Check if the hose is crushed or bent
- If the valve interior is damaged, a new valve should be replaced
Leakage Issues:
- Check if the hose is fully inserted into the barb interface
- Check if hose clamps are loose, retighten if necessary
- Check if the hose is aged or damaged, replace if problems are found
Handle Operation Inflexibility:
- Check if there are foreign objects stuck in the handle rotation shaft
- If jamming is caused by rust, add lubricating oil and switch the valve multiple times
- If the problem is severe, replacement of the valve is recommended
Abnormal Flow:
- Check if the valve interior is blocked by impurities
- Check if the hose is crushed or bent
- If the valve interior is damaged, a new valve should be replaced
Our Commitments & Core Advantages