WENK Pneumatic SCWT Series-Male Tee
Product Detail
Working Media |
Cleaned Air |
Working Pressure |
0.1~1Mpa |
Proof Pressure |
1Mpa |
Working Temperature Range |
0℃~80℃ |
Body Material |
Brass |
SCWT Series Male Tee - User Guide

Product Introduction
The SCWT Series Male Tee is a premium brass pipe fitting manufactured by WENK Pneumatic, specifically designed for creating branch connections in pneumatic and fluid piping systems. This T-shaped fitting features male threaded connections on all three ports, providing a secure and reliable solution for splitting or combining airflow or fluid flow in various industrial applications.
Crafted from high-quality brass, the product offers excellent corrosion resistance and durability, making it suitable for both indoor and outdoor installations. Its compact design allows for easy installation even in tight spaces, while the precision-machined threads ensure a tight seal when properly installed with thread sealant or Teflon tape.

Installation Steps
-
Preparation
- Confirm that the product model and size match your piping system
- Prepare necessary tools: wrench, thread sealant or Teflon tape, cleaning cloth
- Inspect pipes and fittings for damage or impurities
-
Cleaning
- Use a cleaning cloth to wipe the pipe's internal threads and the tee's external threads, ensuring no impurities, oil, or damage
-
Sealing Treatment
- Wrap an appropriate amount of Teflon tape (usually 4-6 turns) evenly in a clockwise direction on all three male threaded ends of the tee
- Or apply an appropriate amount of thread sealant evenly on the threads
-
Main Pipe Connection
- Determine the installation direction of the tee, identifying the main pipe and branch pipe
- Gently hand-tighten one port of the tee into the female-threaded interface of the main pipe
- Ensure proper thread alignment
- Continue hand-tightening until slight resistance is felt
-
Tightening the Main Pipe
- Use a wrench to moderately tighten the connection between the tee and the main pipe, being careful not to over-tighten
- Typically, an additional 1/4 to 1/2 turn with a wrench after hand-tightening is sufficient
-
Connecting the Branch Pipe
- Gently hand-tighten the female-threaded interface of the branch pipe into the branch port of the tee
- Ensure proper thread alignment
- Continue hand-tightening until slight resistance is felt
- Use a wrench to moderately tighten
-
Connecting the Other Main Pipe End
- Repeat steps 4 and 5 to connect the other main pipe end of the tee
-
Inspection
- After installation, check that all connections are secure
- Ensure the tee direction meets design requirements
- Before pressurizing the system, confirm all connections are properly completed
Preparation
- Confirm that the product model and size match your piping system
- Prepare necessary tools: wrench, thread sealant or Teflon tape, cleaning cloth
- Inspect pipes and fittings for damage or impurities
Cleaning
- Use a cleaning cloth to wipe the pipe's internal threads and the tee's external threads, ensuring no impurities, oil, or damage
Sealing Treatment
- Wrap an appropriate amount of Teflon tape (usually 4-6 turns) evenly in a clockwise direction on all three male threaded ends of the tee
- Or apply an appropriate amount of thread sealant evenly on the threads
Main Pipe Connection
- Determine the installation direction of the tee, identifying the main pipe and branch pipe
- Gently hand-tighten one port of the tee into the female-threaded interface of the main pipe
- Ensure proper thread alignment
- Continue hand-tightening until slight resistance is felt
Tightening the Main Pipe
- Use a wrench to moderately tighten the connection between the tee and the main pipe, being careful not to over-tighten
- Typically, an additional 1/4 to 1/2 turn with a wrench after hand-tightening is sufficient
Connecting the Branch Pipe
- Gently hand-tighten the female-threaded interface of the branch pipe into the branch port of the tee
- Ensure proper thread alignment
- Continue hand-tightening until slight resistance is felt
- Use a wrench to moderately tighten
Connecting the Other Main Pipe End
- Repeat steps 4 and 5 to connect the other main pipe end of the tee
Inspection
- After installation, check that all connections are secure
- Ensure the tee direction meets design requirements
- Before pressurizing the system, confirm all connections are properly completed

Precautions
-
Before Installation
- Do not use damaged fittings or pipes
- Ensure the work area is clean to prevent impurities from entering the piping system
- Check that threads are intact and undamaged
- Confirm that the tee specifications and material are suitable for your application
-
During Installation
- Do not use excessive force when tightening to avoid damaging threads or fittings
- Avoid using tools that may damage the fitting surface
- Ensure the tee direction is correct and complies with the piping system design
- For special applications such as natural gas, installation must be performed by professionals
-
In Use
- Do not exceed the product's rated working pressure and temperature range
- Regularly check connection points for signs of leakage or damage
- Avoid contact with sharp objects or severe impact
- Perform maintenance regularly based on medium characteristics
-
Maintenance
- Regularly inspect and maintain according to system usage
- If any damage or leakage is found, replace or repair promptly
- Before reactivating a long-unused system, check the condition of all fittings
Before Installation
- Do not use damaged fittings or pipes
- Ensure the work area is clean to prevent impurities from entering the piping system
- Check that threads are intact and undamaged
- Confirm that the tee specifications and material are suitable for your application
During Installation
- Do not use excessive force when tightening to avoid damaging threads or fittings
- Avoid using tools that may damage the fitting surface
- Ensure the tee direction is correct and complies with the piping system design
- For special applications such as natural gas, installation must be performed by professionals
In Use
- Do not exceed the product's rated working pressure and temperature range
- Regularly check connection points for signs of leakage or damage
- Avoid contact with sharp objects or severe impact
- Perform maintenance regularly based on medium characteristics
Maintenance
- Regularly inspect and maintain according to system usage
- If any damage or leakage is found, replace or repair promptly
- Before reactivating a long-unused system, check the condition of all fittings

Troubleshooting
-
Leakage
- Possible causes
- Insufficient sealing
- Damaged threads
- Insufficient installation torque
- Solutions
- Disassemble and reapply Teflon tape or thread sealant
- Inspect threads and replace if damaged
- Increase tightening appropriately
-
Installation Difficulties
- Possible causes
- Mismatched threads
- Damaged pipes or fittings
- Insufficient installation space
- Solutions
- Confirm thread specifications match
- Inspect and replace damaged components
- Re-evaluate installation location or select other types of fittings
-
Loose Connections
- Possible causes
- Insufficient installation torque
- Excessive pipe vibration
- Material expansion and contraction due to temperature changes
- Solutions
- Increase tightening appropriately
- Inspect and resolve pipe vibration issues
- Confirm operating temperature is within the product's allowable range
Leakage
- Possible causes
- Insufficient sealing
- Damaged threads
- Insufficient installation torque
- Solutions
- Disassemble and reapply Teflon tape or thread sealant
- Inspect threads and replace if damaged
- Increase tightening appropriately
Installation Difficulties
- Possible causes
- Mismatched threads
- Damaged pipes or fittings
- Insufficient installation space
- Solutions
- Confirm thread specifications match
- Inspect and replace damaged components
- Re-evaluate installation location or select other types of fittings
Loose Connections
- Possible causes
- Insufficient installation torque
- Excessive pipe vibration
- Material expansion and contraction due to temperature changes
- Solutions
- Increase tightening appropriately
- Inspect and resolve pipe vibration issues
- Confirm operating temperature is within the product's allowable range

Safety Tips
- During installation and maintenance, please adhere to all relevant safety regulations and standards
- If the system is pressurized, depressurize before performing any operations
- Use appropriate personal protective equipment, such as gloves and safety goggles
- If uncertain, consult a professional technician or contact WENK Pneumatic customer service
This user guide is provided by WENK Pneumatic. For any questions or further technical support, please contact us at any time.