The SG23J Series Solenoid Valve by WENK Pneumatic is a high-performance 2-position 3-way valve designed for precise fluid control in industrial automation systems. Featuring a durable aluminum alloy body with NBR seals, this valve offers reliable operation with a working pressure range suitable for various industrial applications.

Available in multiple configurations with different port sizes and voltage options, the SG23J Series provides versatile solutions for diverse pneumatic control requirements. Its innovative direct-acting structure ensures quick response times and excellent sealing performance, making it suitable for high-pressure applications.

With compact dimensions and multiple mounting options, the SG23J Series Solenoid Valve integrates seamlessly into various pneumatic systems. The valve's robust construction enhances durability and operational stability, making it ideal for use in automation equipment, machinery, and industrial control systems.

Compliant with international standards, WENK Pneumatic's SG23J Series Solenoid Valve delivers consistent performance, easy maintenance, and long service life, making it an ideal choice for your pneumatic control needs.

    Product Detail

    Working Media

    Non-Aggressive Air

    Working Pressure

    0.1~2.4Mpa

    Working Temperature Range

    -5℃~50℃

    Shift Time

    ≤0.06s

    Body Material

    Aluminum Alloy

    SG23J Series Solenoid Valve User Manual

    SG23J(1)

    1. Product Introduction

    The SG23J Series Solenoid Valve is a high-performance 2-position 3-way solenoid valve introduced by WENK Pneumatic, specifically designed for precise fluid control in industrial automation systems. This series features aluminum alloy bodies and nitrile rubber seals, offering compact structure, quick response, and long service life.

    The SG23J Series Solenoid Valve is suitable for various automation equipment, machinery, and industrial control systems. It can be used to control the flow direction of compressed air or other non-corrosive gases, widely applied in bottle blowing machines, pneumatic clamps, automated production lines, and other fields.

    SG23J(2)

    2. Installation Steps

    1. Confirm installation location: Select an appropriate installation position ensuring the valve will not be subject to external interference during operation.

    2. Preparation:

      • Verify that the valve model and specifications meet system requirements
      • Ensure all installation tools are available
      • Clean the installation surface
    3. Valve installation:

      • Choose the appropriate mounting method (base mounting or panel mounting) as needed
      • Secure the valve to the installation position using suitable screws
      • Ensure the valve is firmly installed without looseness
    4. Pneumatic connection:

      • Confirm that the air supply pressure meets the valve's operating requirements
      • Connect the inlet port (P), working port (A), and exhaust port (R) according to the markings on the valve body
      • Use appropriate sealing materials to ensure tight connections without leakage
    5. Electrical connection:

      • Confirm that the power supply voltage matches the valve's rated voltage
      • Connect the power cord according to the wiring diagram
      • Ensure electrical connections are secure and insulation is good
    6. Inspection:

      • Check all connections for correctness
      • Ensure the valve can operate freely after installation

    SG23J(3)

    3. Operation Guide

    1. Valve operation:

      • When energized, the valve switches to the working position, connecting the inlet port (P) with the working port (A)
      • When de-energized, the valve resets to the initial position, connecting the working port (A) with the exhaust port (R)
      • Remote control of the valve can be achieved through control signals
    2. Working principle:

      • The solenoid valve controls the movement of the valve core through the energization and de-energization of the electromagnetic coil
      • The movement of the valve core changes the connection method of the air circuit, thereby controlling the direction of fluid flow
      • Adopting a direct-acting structure, it provides quick response and reliable operation
    3. Notes:

      • Do not exceed the valve's maximum working pressure and temperature range
      • Avoid use in environments with strong vibration or impact
      • Keep the valve clean to prevent dust and impurities from entering the valve body
      • Ensure stable power supply voltage to avoid excessive voltage fluctuations

    SG23J(4)

    4. Maintenance

    1. Regular inspection:

      • Check for valve leakage
      • Verify normal valve operation
      • Ensure connections are secure
      • Check that electrical connections are in good condition
    2. Cleaning:

      • Regularly clean the external surface of the valve to remove dust and dirt
      • If impurities are found inside the valve, clean them promptly
    3. Lubrication:

      • Regularly add an appropriate amount of lubricating oil to the valve's moving parts
      • Use lubricating oil compatible with nitrile rubber
    4. Storage:

      • For long-term storage, store the valve in a dry, clean, and ventilated environment
      • Storage temperature should be between -5°C and 40°C
      • Avoid direct sunlight and high-temperature environments

    SG23J(5)

    5. Troubleshooting

    1. Valve fails to operate

      • Possible causes:
        • Power failure or voltage mismatch
        • Damaged coil
        • Valve core stuck
      • Solutions:
        • Check power supply and voltage
        • Replace the coil
        • Clean or replace the valve core
    2. Valve leakage

      • Possible causes:
        • Damaged seals
        • Loose connections
        • Damaged valve body
      • Solutions:
        • Replace seals
        • Tighten connections
        • Replace the valve body
    3. Unstable valve operation

      • Possible causes:
        • Unstable air supply pressure
        • Excessive voltage fluctuations
        • Worn valve core
      • Solutions:
        • Stabilize air supply pressure
        • Stabilize power supply voltage
        • Replace the valve core
    4. Coil overheating

      • Possible causes:
        • Excessive voltage
        • Coil short circuit
        • Frequent valve operation
      • Solutions:
        • Check power supply voltage
        • Replace the coil
        • Reduce valve operation frequency

    SG23J(1)

    6. Safety Precautions

    1. Before installation and maintenance, ensure the air supply and power are cut off.

    2. Do not exceed the valve's maximum working pressure and temperature range.

    3. Follow relevant safety regulations and operating procedures during installation and operation.

    4. If any valve abnormalities are found, stop using it immediately and conduct inspections and repairs.

    5. Do not disassemble or modify the valve arbitrarily to avoid affecting performance or causing safety accidents.

    SG23JD高压电磁阀

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.