WENK Pneumatic SRC/ACK Swing Cylinder(90°/180°)
Product Detail
Acting Mode |
Double Acting |
Working Media |
Air (Filtered through ≥40μm mesh) |
Working Pressure |
0.15~1.0Mpa |
Working Temperature Range |
-20℃~70℃ |
Piston Speed |
50~200mm/s |
Body Material |
Aluminum Alloy |
SRC/ACK Series Rotary Clamp Cylinder User Guide

Product Overview
The SRC/ACK series rotary clamp cylinder from WENK Pneumatic is a versatile pneumatic actuator designed for precision clamping and positioning applications in automated systems. This series combines rotational and linear motion to provide efficient workpiece clamping, featuring 90° or 180° rotation angles and vertical stroke movement.
The SRC/ACK series utilizes a double-acting design with bore sizes ranging from 25mm to 63mm, meeting various clamping force and installation space requirements. Constructed with high-quality aluminum alloy, these cylinders offer strength while maintaining lightweight properties. Widely used in CNC machines, assembly lines, and automated production equipment, they excel in applications requiring quick clamping and release cycles.
This series provides both left (L) and right (R) rotation options for flexible configuration based on specific application needs. The compact design saves valuable space while delivering powerful clamping force, making it an essential component in modern manufacturing environments.

Product Specifications
Basic Parameters
- Bore Size: 25mm, 32mm, 40mm, 50mm, 63mm
- Action Type: Double-acting
- Rotation Angle: 90°, 180° (custom angles available)
- Rotation Direction: Left (L), Right (R)
- Vertical Stroke:
- 25mm bore: 11mm
- 32mm bore: 13mm
- 40mm bore: 13mm
- 50mm bore: 15mm
- 63mm bore: 15mm
- Operating Pressure Range: 0.15~1.0MPa
- Maximum Operating Pressure: 1.05MPa
- Ambient and Fluid Temperature: 0~60°C
- Piston Speed: 30~500mm/s
- Cushioning: Rubber cushioning
- Lubrication: Lubrication-free design
- Port Size: M5×0.8 (25mm bore), PT1/8 (32~63mm bore)
- Mounting Type: Flange mounting
- Clamp Type: Single-sided clamp, Double-sided clamp (Type D)
- 25mm bore: 11mm
- 32mm bore: 13mm
- 40mm bore: 13mm
- 50mm bore: 15mm
- 63mm bore: 15mm
Clamping Force (N)
- 25mm bore:
- 0.5MPa: 392N
- 0.7MPa: 549N
- 1.0MPa: 785N
- 32mm bore:
- 0.5MPa: 631N
- 0.7MPa: 884N
- 1.0MPa: 1262N
- 40mm bore:
- 0.5MPa: 981N
- 0.7MPa: 1374N
- 1.0MPa: 1962N
- 50mm bore:
- 0.5MPa: 1533N
- 0.7MPa: 2147N
- 1.0MPa: 3066N
- 63mm bore:
- 0.5MPa: 2493N
- 0.7MPa: 3490N
- 1.0MPa: 4986N
- 0.5MPa: 392N
- 0.7MPa: 549N
- 1.0MPa: 785N
- 0.5MPa: 631N
- 0.7MPa: 884N
- 1.0MPa: 1262N
- 0.5MPa: 981N
- 0.7MPa: 1374N
- 1.0MPa: 1962N
- 0.5MPa: 1533N
- 0.7MPa: 2147N
- 1.0MPa: 3066N
- 0.5MPa: 2493N
- 0.7MPa: 3490N
- 1.0MPa: 4986N

Installation Steps
-
Pre-installation Preparation
- Verify that the cylinder model and specifications meet application requirements
- Inspect the cylinder for any external damage
- Clean the mounting surface, ensuring no impurities or burrs
- Prepare necessary installation tools and accessories
-
Mounting Position Selection
- Determine the cylinder mounting position based on workpiece shape and processing requirements
- Ensure no obstacles within the cylinder's rotation range
- Reserve sufficient space for cylinder rotation and vertical movement
- Ensure the mounting surface has sufficient strength to withstand clamping force
-
Secure Installation
- Fix the cylinder to the mounting surface using bolts
- Ensure the cylinder is securely installed without looseness
- Check that cylinder rotation is smooth without jamming
- Adjust the cylinder rotation direction (left or right) as needed
-
Piping Connection
- Identify the cylinder's air inlet and exhaust ports
- Connect to M5 or PT1/8 ports using appropriate air tubes and fittings
- Ensure piping is tightly sealed without leakage
- Install speed controllers if needed to adjust cylinder operating speed
-
Magnetic Switch Installation (Optional)
- Select the appropriate magnetic switch model
- Install the magnetic switch in the switch groove on the cylinder body
- Adjust the switch position to ensure triggering at the desired position
- Connect switch signal wires to the control system
Pre-installation Preparation
- Verify that the cylinder model and specifications meet application requirements
- Inspect the cylinder for any external damage
- Clean the mounting surface, ensuring no impurities or burrs
- Prepare necessary installation tools and accessories
Mounting Position Selection
- Determine the cylinder mounting position based on workpiece shape and processing requirements
- Ensure no obstacles within the cylinder's rotation range
- Reserve sufficient space for cylinder rotation and vertical movement
- Ensure the mounting surface has sufficient strength to withstand clamping force
Secure Installation
- Fix the cylinder to the mounting surface using bolts
- Ensure the cylinder is securely installed without looseness
- Check that cylinder rotation is smooth without jamming
- Adjust the cylinder rotation direction (left or right) as needed
Piping Connection
- Identify the cylinder's air inlet and exhaust ports
- Connect to M5 or PT1/8 ports using appropriate air tubes and fittings
- Ensure piping is tightly sealed without leakage
- Install speed controllers if needed to adjust cylinder operating speed
Magnetic Switch Installation (Optional)
- Select the appropriate magnetic switch model
- Install the magnetic switch in the switch groove on the cylinder body
- Adjust the switch position to ensure triggering at the desired position
- Connect switch signal wires to the control system

Operation Guide
-
Pre-start Check
- Verify that the air supply pressure is within the specified range
- Check that piping connections are correct
- Ensure the operating environment temperature is within the allowable range
- Verify that the cylinder is securely installed
- Ensure no obstacles within the rotation range
-
Basic Operation
- Clamping Action:
- Compressed air enters from one port, driving the piston to rotate (90° or 180°)
- After rotating into position, the piston performs a vertical downward movement
- Workpiece clamping is completed
- Unclamping Action:
- Compressed air enters from the other port, driving the piston to rise vertically
- After rising into position, the piston rotates back to its original position
- Workpiece unclamping is completed
-
Pressure Adjustment
- Adjust the operating air pressure based on workpiece material and clamping requirements
- Higher air pressure results in greater clamping force
- Ensure air pressure does not exceed the maximum operating pressure of 1.0MPa
- Select appropriate minimum operating pressure based on bore size
-
Speed Adjustment
- Adjust cylinder operating speed using speed controllers
- Turn the speed controller knob clockwise to decrease speed
- Turn the speed controller knob counterclockwise to increase speed
- Ensure speed is within the range of 30~500mm/s
-
Operational Precautions
- Avoid exceeding the cylinder's maximum clamping force
- Do not suddenly load or unload during cylinder movement
- Avoid lateral loads to prevent affecting cylinder life and performance
- Regularly check that cylinder movement is smooth and free of abnormal noise
Pre-start Check
- Verify that the air supply pressure is within the specified range
- Check that piping connections are correct
- Ensure the operating environment temperature is within the allowable range
- Verify that the cylinder is securely installed
- Ensure no obstacles within the rotation range
Basic Operation
- Clamping Action:
- Compressed air enters from one port, driving the piston to rotate (90° or 180°)
- After rotating into position, the piston performs a vertical downward movement
- Workpiece clamping is completed
- Unclamping Action:
- Compressed air enters from the other port, driving the piston to rise vertically
- After rising into position, the piston rotates back to its original position
- Workpiece unclamping is completed
Pressure Adjustment
- Adjust the operating air pressure based on workpiece material and clamping requirements
- Higher air pressure results in greater clamping force
- Ensure air pressure does not exceed the maximum operating pressure of 1.0MPa
- Select appropriate minimum operating pressure based on bore size
Speed Adjustment
- Adjust cylinder operating speed using speed controllers
- Turn the speed controller knob clockwise to decrease speed
- Turn the speed controller knob counterclockwise to increase speed
- Ensure speed is within the range of 30~500mm/s
Operational Precautions
- Avoid exceeding the cylinder's maximum clamping force
- Do not suddenly load or unload during cylinder movement
- Avoid lateral loads to prevent affecting cylinder life and performance
- Regularly check that cylinder movement is smooth and free of abnormal noise

Maintenance
-
Daily Inspection
- Check for piping leaks
- Verify smooth cylinder operation
- Check for loose mounting bolts
- Verify no abnormal cylinder noise or vibration
-
Regular Maintenance
- Every 3 months:
- Clean the cylinder exterior
- Check installation status
- Verify operational performance
- Every 6 months:
- Inspect seal condition
- Perform functional tests
- Annually:
- Inspect bearing and rotating component wear
- Check internal spring performance
-
Lubrication
- The SRC/ACK series features a lubrication-free design and typically requires no additional lubrication
- If used for extended periods or in harsh environments, an appropriate amount of lubricating oil may be added as needed
- Use recommended lubricant types and avoid incompatible lubricants
-
Storage and Handling
- Store in a dry, clean environment away from direct sunlight
- Avoid storage temperatures below 0°C or above 60°C
- Avoid severe impact and vibration during handling
- Inspect the cylinder for damage before installation
Daily Inspection
- Check for piping leaks
- Verify smooth cylinder operation
- Check for loose mounting bolts
- Verify no abnormal cylinder noise or vibration
Regular Maintenance
- Every 3 months:
- Clean the cylinder exterior
- Check installation status
- Verify operational performance
- Every 6 months:
- Inspect seal condition
- Perform functional tests
- Annually:
- Inspect bearing and rotating component wear
- Check internal spring performance
Lubrication
- The SRC/ACK series features a lubrication-free design and typically requires no additional lubrication
- If used for extended periods or in harsh environments, an appropriate amount of lubricating oil may be added as needed
- Use recommended lubricant types and avoid incompatible lubricants
Storage and Handling
- Store in a dry, clean environment away from direct sunlight
- Avoid storage temperatures below 0°C or above 60°C
- Avoid severe impact and vibration during handling
- Inspect the cylinder for damage before installation

Safety Precautions
- Read this user guide carefully before operation
- Ensure air supply pressure is within specified range to avoid equipment damage or safety incidents
- Cut off air supply before installation and maintenance
- Avoid use in environments with corrosive gases, dust, or high temperatures unless specially treated
- Do not exceed the equipment's rated load and operating frequency
- Regularly inspect equipment condition to identify and address potential issues promptly
- Immediately stop use and inspect if abnormal conditions are found
- Avoid placing fingers or other body parts within the cylinder's movement range
- Use appropriate safety protection devices, such as protective covers or safety light curtains
- Release internal pressure before cylinder disassembly
- Do not disassemble or modify the cylinder to avoid affecting safety performance
- Use original accessories when replacing components