0102030405
WENK Pneumatic ST Series Foot Valve
Product Detail
| Model | ST-402 | ST-402A | ST-403 | ST-403A | |
| Working Media | Clean air | ||||
| Action Mode | Direct-acting Type | ||||
| Max.Working Pressure | 0.8Mpa | ||||
| Proof Pressure | 1.0MPa | ||||
| Working Temperature Range | 0℃~60℃ | ||||
| Port Size | G1/4 | G3/8 | |||
| Lubrication | No Need | ||||
| Material | Body | Aluminum Alloy | |||
| Seal | NBR | ||||
ST Series Foot Valve User Guide

Product Overview
The ST Series Foot Valve is a high-quality pneumatic control component designed by WENK Pneumatic. Operated by foot pedal, it controls pneumatic circuits with compact structure and reliable performance, suitable for various industrial automation applications.

Technical Specifications
-
Model Specifications
- ST-402/612: G1/4" Port
- ST-403/632: G3/8" Port
-
Operation Type
- Fixed: No Code
- A: Spring Return Type
Working Medium: Clean compressed air
Working Pressure Range: 0.15-0.8MPa
Ambient Temperature: 0~60℃
Body Material: Aluminum Alloy
Seal Material: NBR (Nitrile Butadiene Rubber)
Model Specifications
- ST-402/612: G1/4" Port
- ST-403/632: G3/8" Port
Operation Type
- Fixed: No Code
- A: Spring Return Type
Working Medium: Clean compressed air
Working Pressure Range: 0.15-0.8MPa
Ambient Temperature: 0~60℃
Body Material: Aluminum Alloy
Seal Material: NBR (Nitrile Butadiene Rubber)

Installation Steps
-
Confirm Installation Location
- Select a stable mounting surface
- Ensure sufficient operating space
- Avoid installation in high temperature, humid, or corrosive environments
-
Connect Air Supply
- Confirm air supply pressure is within 0.15-0.8MPa range
- Connect air inlet (P), outlet (A/B), and exhaust (R) according to valve markings
- Use appropriate sealing materials to ensure tight connections
-
Secure the Valve Body
- Firmly fix the valve body to the mounting surface with screws
- Ensure the valve body does not move or vibrate during operation
Confirm Installation Location
- Select a stable mounting surface
- Ensure sufficient operating space
- Avoid installation in high temperature, humid, or corrosive environments
Connect Air Supply
- Confirm air supply pressure is within 0.15-0.8MPa range
- Connect air inlet (P), outlet (A/B), and exhaust (R) according to valve markings
- Use appropriate sealing materials to ensure tight connections
Secure the Valve Body
- Firmly fix the valve body to the mounting surface with screws
- Ensure the valve body does not move or vibrate during operation

Operation Guide
-
Basic Operation
- Fixed Type:
- Press the foot pedal: Valve switches to working position, air supply connected
- Press the foot pedal again: Valve returns to initial position, air supply disconnected
- Type A (Spring Return Type):
- Press the foot pedal: Valve switches to working position, air supply connected
- Release the foot pedal: Valve returns to initial position under spring force, air supply disconnected
-
Operation Precautions
- Avoid excessive force when pressing the foot pedal
- Operation frequency should not be too fast, recommended no more than 30 times per minute
- Regularly check the elasticity of the foot pedal return spring (Type A only)
Basic Operation
- Fixed Type:
- Press the foot pedal: Valve switches to working position, air supply connected
- Press the foot pedal again: Valve returns to initial position, air supply disconnected
- Type A (Spring Return Type):
- Press the foot pedal: Valve switches to working position, air supply connected
- Release the foot pedal: Valve returns to initial position under spring force, air supply disconnected
Operation Precautions
- Avoid excessive force when pressing the foot pedal
- Operation frequency should not be too fast, recommended no more than 30 times per minute
- Regularly check the elasticity of the foot pedal return spring (Type A only)

Maintenance
-
Daily Inspection
- Check for air leakage at all connection points
- Ensure smooth operation of the foot pedal without sticking
- Clean dust and debris from the valve body surface
-
Regular Maintenance
- Every 3 months: Inspect and clean the air inlet filter
- Every 6 months: Check the condition of seals and replace if necessary
- Annually: Perform comprehensive performance testing
-
Lubrication
- No additional lubrication required
- If increased operating resistance is noticed, add a small amount of pneumatic-specific lubricating oil to moving parts
Daily Inspection
- Check for air leakage at all connection points
- Ensure smooth operation of the foot pedal without sticking
- Clean dust and debris from the valve body surface
Regular Maintenance
- Every 3 months: Inspect and clean the air inlet filter
- Every 6 months: Check the condition of seals and replace if necessary
- Annually: Perform comprehensive performance testing
Lubrication
- No additional lubrication required
- If increased operating resistance is noticed, add a small amount of pneumatic-specific lubricating oil to moving parts

Safety Precautions
- Ensure air supply is cut off before installation and maintenance
- Do not exceed the rated pressure
- Avoid use in environments with explosive gases
- Regularly inspect valve condition and stop use immediately if abnormalities are found
- Non-professionals should not disassemble internal valve structures

Our Commitments & Core Advantages
1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.