The TAC Series Mechanical Valve by WENK Pneumatic represents a premium line of precision-engineered pneumatic control valves designed for versatile industrial applications. These compact yet rugged valves feature a robust construction with stainless steel stems and nickel-plated brass bodies, ensuring durability and reliable performance even in demanding environments.

Available in 2-position, 3-way and 5-way configurations, the TAC Series offers flexible flow control solutions with operating pressure ranges suitable for various industrial systems. The valves incorporate advanced sealing technology for excellent airtight performance and feature multiple actuation options including push button, toggle lever, and roller lever designs.

Engineered for easy installation and maintenance, these valves provide efficient pneumatic circuit control with low power consumption. Ideal for automation systems, manufacturing equipment, and process control applications, the TAC Series Mechanical Valves deliver consistent performance and long service life, making them a trusted choice for industrial professionals worldwide.

    Product Detail

    Model 2 3 4 31 41
    Number of Ports 2(NC) 3(NC) 5 3 5
    Ambient Temperature 0℃~60℃
    Sonic conduction C(dm³/(s·bar)a) 0.36 0.36 0.5 0.36 0.5
    Effective Flow Area[Cv Value](mm²) 1.8[0.08] 1.8[0.08] 2.5[0.12] 1.8[0.08] 2.5[0.12]
    Port Size M5 x 0.8
    Working Pressure 0~0.9 Mpa
    Proof Pressure 1.35Mpa
    Material Body Nickel-Plated Brass

    TAC Series Mechanical Valve User Manual

    TAC(1)

    Product Overview

    The TAC Series Mechanical Valves by WENK Pneumatic are high-quality pneumatic control components designed for various industrial automation systems. This series of valves adopts advanced sealing technology and high-quality materials to ensure long-term stable operation and reliable performance.

    TAC(2)

    Installation Steps

    1. Pre-installation Preparation

      • Verify that the valve model matches system requirements
      • Inspect the valve for damage or contamination
      • Prepare necessary installation tools and sealing materials
    2. Installation Methods

      • Body mounting: Secure the valve body directly to the mounting plate using screws
      • Panel mounting: Fix the valve to the control panel through panel mounting holes
    3. Piping Connection

      • Ensure pipes are clean and free of contaminants and moisture
      • Use appropriate sealing material (such as PTFE tape) on threads
      • Connect inlet pipe (P), outlet pipes (A/B), and exhaust pipes (R/S) according to the markings on the valve body
      • Avoid over-tightening to prevent thread damage
    4. Installation Precautions

      • Install the valve in a location convenient for operation and maintenance
      • Avoid installation near heat sources or vibration sources
      • Ensure the valve's operating direction meets system design requirements

    TAC(3)

    Operation Guide

    1. Manual Operation Type

      • Push button type: Press the button to switch the valve, which automatically resets when released
      • Knob type: Rotate the knob to switch valve status, which can be locked in different positions
      • Lever type: Toggle the lever to control valve action, with different reset methods depending on the model
    2. Mechanical Operation Type

      • Roller type: Push the roller through an external mechanical device to switch the valve
      • Pay attention to the control stroke to avoid damage caused by exceeding the specified range
    3. Operation Precautions

      • Avoid using excessive force during operation to prevent valve damage
      • Regularly check if the operating mechanism is flexible and free of jamming
      • Stop use immediately and inspect if any abnormalities are found

    TAC(4)

    Maintenance

    1. Daily Inspection

      • Check for air leakage
      • Inspect if the operating mechanism is flexible
      • Verify that connecting pipes are secure
    2. Regular Maintenance

      • Every 3 months: Clean the external surface of the valve and check connection tightness
      • Every 6 months: Inspect the condition of seals and replace if necessary
      • Annually: Conduct a comprehensive inspection, including disassembly to check internal components
    3. Maintenance Precautions

      • Always cut off the air supply and release system pressure before maintenance
      • Use recommended lubricants (if applicable)
      • Avoid using corrosive cleaning agents
      • Pay attention to the correct installation position of parts when reassembling after maintenance

    TAC(5)

    Safety Precautions

    1. Ensure the system is depressurized before installation and maintenance
    2. Avoid inserting fingers or other body parts into the valve's moving range during operation
    3. Regularly check the valve status and stop use immediately if abnormalities are found
    4. Do not exceed the valve's rated working pressure and temperature range
    5. Do not strike valve operating components with sharp tools
    6. If abnormal noise or vibration is detected, inspect immediately

    TAC机械阀

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset