Leave Your Message
WENK Pneumatic YBPY Series-Union “Y”
Products
Products Categories
Featured Products

WENK Pneumatic YBPY Series-Union “Y”

The YBPY Series Y-Type Union from WENK Pneumatic is a high-quality three-way pipe connector designed for pneumatic systems. This Y-type fitting enables the connection of three tubes in a branching configuration, providing an efficient solution for splitting or combining air flow in complex piping systems.

Featuring a compact design with one-touch push-in connections, the YBPY Series allows for quick and tool-free installation. The precision-engineered stainless steel grab-ring securely grips polyurethane (PU) tubing, ensuring a reliable and leak-free connection even under vibration and pressure fluctuations.

Constructed from durable materials, the YBPY Series Y-Type Union offers excellent corrosion resistance and long service life in demanding industrial environments. Available in multiple sizes (4mm, 6mm, 8mm, 10mm, 12mm) to accommodate different tube diameters, this versatile fitting is suitable for a wide range of pneumatic applications requiring efficient air distribution or combination.

    Product Detail

    Working Pressure

    0.1~1Mpa

    Proof Pressure

    1Mpa

    Working Temperature Range

    0℃~60℃

    Applicable Pipe

    PU Tube

    Body Material

    Plastic

    YBPY Series Y-Type Union - User Guide

    YBPY(1)

    Introduction

    Thank you for choosing the YBPY Series Y-Type Union from WENK Pneumatic. This high-quality three-way fitting is designed for use in pneumatic systems to connect and branch air lines efficiently. The one-touch push-in design allows for quick and easy installation without the need for tools.

    YBPY(2)

    Features

    • One-touch push-in connection for easy installation
    • Compact design saves space in piping systems
    • Stainless steel grab-ring ensures secure tube retention
    • NBR seal provides reliable leak-proof performance
    • Suitable for use with PU, PE, and PA tubing
    • Wide operating temperature range (0°C to +60°C)
    • RoHS compliant

    YBPY(3)

    Installation Instructions

    Tools Required

    • None (tool-free installation)

    Preparation

    1. Ensure the tube end is cut straight and clean
    2. Remove any burrs or debris from the tube end
    3. Check that the tube diameter matches the fitting size
    4. Verify that the system pressure is within the fitting's rated pressure

    Installation Steps

    1. Insert the tube into the fitting until it reaches the tube stop

      • You will feel a slight resistance when the tube passes the grab-ring
      • Continue pushing until the tube bottoms out against the stop
    2. Pull gently on the tube to confirm it is securely held in place

      • The tube should not come out when pulled lightly
    3. For threaded connections:

      • Apply thread sealant or Teflon tape to the male threads if necessary
      • Screw the fitting into the threaded port by hand
      • Tighten with a wrench if needed (do not over-tighten)

    YBPY(4)

    Removal Instructions

    1. Push the collet (release ring) straight in towards the fitting body
    2. While holding the collet in, pull the tube out of the fitting
    3. If the tube is difficult to remove, slight twisting may help

    Maintenance

    • Regularly inspect fittings for signs of damage or leakage
    • Check tube connections to ensure they remain secure
    • Clean fittings periodically to remove dust and debris
    • Replace any damaged or worn fittings immediately

    YBPY(5)

    Troubleshooting

    Leakage at Tube Connection

    • Check that the tube is fully inserted into the fitting
    • Verify that the tube diameter matches the fitting size
    • Inspect the tube for cracks, damage, or cuts
    • Ensure the grab-ring is not damaged or worn
    • Replace the fitting if leakage persists

    Tube Cannot Be Inserted

    • Check that the tube diameter is correct for the fitting
    • Ensure the tube end is cut straight and is not damaged
    • Verify that the collet is not stuck or damaged
    • Inspect the fitting for any internal obstructions

    Tube Cannot Be Removed

    • Ensure the collet is being pushed in fully
    • Check for any damage to the collet or release mechanism
    • Use pliers to gently pull the tube while holding the collet
    • Replace the fitting if the tube cannot be removed

    YBPY(1)

    Safety Precautions

    • Always wear appropriate personal protective equipment when working with pneumatic systems
    • Ensure the system is depressurized before installing or removing fittings
    • Do not exceed the maximum working pressure or temperature ratings
    • Use only compatible fluids and gases (compressed air only)
    • Follow all applicable safety regulations and guidelines

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.
    YBPY接管_01

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset