The YHPL-C Series from WENK Pneumatic represents premium miniature threaded elbow fittings designed for precision pneumatic systems. These compact 90° elbow connectors feature a robust brass nickel-plated body with stainless steel components, ensuring reliable performance in compressed air applications. With working pressure up to 1.0MPa and temperature resistance from 0-60°C, they provide secure, leak-proof connections for PU/PVC tubing in tight installation spaces. Available in multiple thread sizes including M3, M4, M5, and M6, these fittings offer versatile solutions for automated machinery, medical equipment, and precision instruments requiring efficient air flow management.

    Product Detail

    Working Media

    Cleaned Air

    Working Pressure

    0.1~1Mpa

    Proof Pressure

    1.0Mpa

    Working Temperature Range

    0℃~80℃

    Body Material

    Plastic

    YHPL-C Series Miniature Threaded Elbow Fitting User Guide

    YHPL-C(1)

    1. Product Introduction

    The YHPL-C Series miniature threaded elbow fitting is a high-quality pneumatic connection component introduced by WENK Pneumatic, specifically designed for precision pneumatic systems with limited space.

    • Product Features:

      • 90° elbow design, suitable for pipeline systems requiring direction change
      • Compact size, saving approximately 40% space compared to standard types
      • Elliptical release ring design for quick tube assembly and disassembly
      • Stainless steel clamping claws securely fix the tube without damaging the surface
      • Nitrile rubber sealing ring ensures reliable sealing
    • Application Scenarios:

      • Automated machinery and equipment
      • Medical devices
      • Precision instruments and meters
      • Pneumatic systems with limited space
    YHPL-C(2)

    2. Installation Instructions

    2.1 Preparation

    • Ensure the working environment is clean, free of dust and impurities
    • Prepare necessary tools: appropriate wrench, tube cutting tool
    • Check if the tube meets specification requirements (PU or PVC material)

    2.2 Installation Steps

    1. Tube Preparation:

      • Use a dedicated cutting tool to cut the tube vertically, ensuring a flat cut
      • Remove burrs and dust from the tube port
    2. Thread Connection:

      • Screw the threaded end of the fitting into the equipment interface
      • Tighten with an appropriate wrench (Note: Use appropriate tools for M3 threads to avoid excessive force)
      • For occasions requiring sealing, Teflon tape can be used for auxiliary sealing
    3. Tube Connection:

      • Ensure the tube cut is clean
      • Firmly insert the tube into the fitting until it cannot be pushed further
      • Gently pull the tube to confirm it is securely connected

    YHPL-C(3)

    3. Usage Method

    3.1 Working Parameters

    • Applicable Fluid: Clean compressed air
    • Working Pressure: 0.1-1.0MPa
    • Working Temperature: 0-80°C
    • Applicable Tube: PU or PVC material

    3.2 Operating Precautions

    • Ensure system pressure does not exceed the maximum working pressure of 1.0MPa
    • Avoid use in environments beyond the temperature range
    • Regularly check if the tube connection is secure
    • Do not forcefully insert or remove the tube while the system is running

    3.3 Disassembly Method

    • Pinch the elliptical release ring with thumb and index finger
    • Pull out the tube outward simultaneously
    • If the fitting needs to be disassembled, use appropriate tools to unscrew the threaded part

    YHPL-C(4)

    4. Maintenance

    4.1 Daily Inspection

    • Regularly check if the fitting has leakage
    • Check if the tube has aging, cracks, or damage
    • Confirm if the threaded connection part is loose

    4.2 Cleaning and Maintenance

    • Use dry, clean compressed air to blow off the fitting surface
    • If necessary, wipe the fitting surface with a neutral detergent
    • Avoid using corrosive solvents for cleaning

    4.3 Storage Method

    • Unused fittings should be stored in a dry, clean environment
    • Avoid direct sunlight and high-temperature environments
    • Recommended storage temperature is between -10°C and 40°C

    YHPL-C(5)

    5. Troubleshooting

    5.1 Common Problems and Solutions

    1. Tube leakage

      • Uneven tube cut: Re-cut the tube, ensuring a vertical and flat cut
      • Tube not fully inserted: Ensure the tube is fully inserted to the bottom of the fitting
      • Damaged sealing ring: Replace with a new fitting
    2. Threaded connection leakage

      • Thread not tightened: Properly tighten with a wrench
      • Poor thread sealing: Use Teflon tape for auxiliary sealing
    3. Difficulty inserting tube

      • Impurities inside the fitting: Clean the inside of the fitting
      • Incorrect tube size: Use the correct specification of tube

    Our Commitments & Core Advantages

    1. We are a factory specializing in the production of pneumatic components, with mature manufacturing experience and technology.
    2. We manufacture and supply a wide range of series and specifications of air cylinders and pneumatic components, providing you with flexible options.
    3. We can undertake the customization business of various pneumatic components according to the specific needs of customers.
    We adhere to the service concept of efficiency and thoughtfulness, making you feel comfortable throughout the cooperation process, just as smooth as cooperating with a close friend.
    YHPL-C弯通_01

    Make an free consultant

    Your Name*

    Phone Number

    Country

    Remarks*

    reset